Johnson Millennium | Section - 7 Appendix |
REQUEST ONE PRESET (01h)
SYS_HEAD, 01(h), yy1, yy2, zz1, zz2 F7(h)
When yy = 00(h) | User bank is selected |
When yy = 01(h) | Factory bank is selected |
zz | The Preset number, |
When a Request One Preset procedure is received, the Millennium will respond with a Receive One Preset procedure.
RECEIVE ONE PRESET (42h)
SYS_HEAD 42(h), vv(1)1, vv(1)2, vv(2)1, vv(2)2, yy1, yy2, zz1, zz2, dd(1st)1,dd(1st)2, ... dd(nth)1, dd(nth)2, F7(h)
vv software version number |
|
When yy = 00(h) | User bank is selected |
When yy = 01(h) | Factory bank is selected |
zz | The Preset number, |
dd(n) | Preset data |
The Receive One Preset procedure is used to load a preset into the Millennium. The number of preset bytes to be received (n) is different for each preset. If the Millennium is sent a Receive One Preset procedure where the preset number is not a valid RAM destination, it will be ignored.
REQUEST BULK DUMP (49h)
SYS_HEAD, 49(h), F7(h)
When a Request Bulk Dump procedure is received, the Millennium will respond with a Receive Bulk Dump procedure.
RECEIVE BULK DUMP (48h)
SYS_HEAD 48(h), dd(1st)1 dd(1st)2, ... dd(nth)1, dd(nth)2, F7(h)
dd(n) | Bulk Dump Data |
The Receive Bulk Dump procedure is used to load all User Programs into the Millennium. A software version number is imbedded in the data.
REQUEST UTILITY SETTINGS (11h)
SYS_HEAD, 11(h), F7(h)
When a Request Utility Settings procedure is received, the Millennium will respond with a Receive Utility Settings procedure.
User Guide