TROUBLESHOOTING

Refer to this page to determine the cause of a problem you are experiencing with your camera.

Problem

Check the following

 

 

No display is in the data

Is the battery installed correctly?

panel when the main

Is the battery exhausted?

switch is set to ON

 

 

 

Autofocus does not

Is M. FOCUS displayed in the data

operate when the shutter-

panel?

release button is pressed

Is the subject in one of the special

partway down.

focusing situations listed on page 30?

 

 

 

 

How close is the camera to the

 

subject?

 

 

Shutter will not release.

Is the lens compatible? Is the lens

 

attached properly?

 

 

 

Is Autofocus-release priority (AF

 

priority) selected?

 

 

 

Is the camera attached to a

 

telescope?

 

 

is displayed in the data

 

panel.

 

 

 

appears in the data

Is Data Memory on?

panel.

Are all the film areas full?

 

 

124

If the information does not cover the problem you are experiencing or the condition continues, contact a Minolta Service Facility.

Solution

Page

 

 

Install a new battery if the battery is dead.

12

 

 

Press the Focus-mode button to select autofocus.

31

 

 

Use focus lock or focus the lens manually.

27, 31

 

 

Make sure you are not closer than the minimum focus

distance listed in the lens' instruction manual.

 

 

 

Use a compatible lens and attach it properly.

14,121

 

 

In AF priority, the shutter will not release unless sharp

69

focus is confirmed. To release the shutter even if focus is

not confirmed, switch to Release priority.

 

 

 

Contact a Minolta Service Facility before attaching the

camera to a telescope.

 

 

 

Remove and reinstall the battery. If normal camera

 

operation does not resume, contact a Minolta Service

12

Facility.

 

 

 

To begin overwriting film area 1, take the next picture.

106

 

 

 

 