2-5 Auto vane control

 

 

SWING

 

TIMER OFF TIMER

CLOCK AUTO AUTO

FAN

 

CHECK SET TEMP.

START STOP

FILTER

SPEED

 

 

AUTO

CHECK MODE

 

 

RETURN

TEST RUN

1 Horizontal

2 20° downward

3 40° downward

4 60° downward

5 swing

<How to operate>

To change the air flow direction, press AIR DISCHARGE button.

1

2

3

4

5

Horizontal

20°

40°

60°

SWING

Available in COOL operation with fan speed on HIGH or in HEAT operation.

Unavailable in DRY operation.

If fan speed changes from HIGH to LOW during 20° downward airflow in COOL mode, the direction automat- ically changes to horizontal.

Changes by pressing the AIR DISCHARGE button.

(1) COOL/DRY operation

At the start-up of COOL or DRY operation, the airflow direction in automatically set to horizontal. After, it can be changed to another direction with AIR DISCHARGE button on the remote controller.

<Auto return>

When 40° or 60° airflow is set with fan speed in LOW, “AUTO RETURN” appears right side of the air direction. One hour later the direction changes to horizontal degrees, automatically and “AUTO RETURN” disappears.

(2) HEAT operation

At the start-up of HEAT operation, airflow direction depends on the setting of the last operation.

After, it can be changed to another direction with AIR DISCHARGE button. The airflow direction shifts to horizontal regard- less of the remote controller settings under any of the following conditions.

Thermostat OFF

Defrosting

Indoor fan speed EXTRA-LOW in hot adjustment