2-6 TIMER operation
WIRED REMOTE CONTROLLER
|
| SWING |
| |
TIMER OFF TIMER | CLOCK AUTO AUTO | FAN |
| |
CHECK SET TEMP. | START STOP | FILTER | ||
SPEED | ||||
|
| AUTO | CHECK MODE | |
|
| RETURN |
TEST RUN
<Timer setting example>
AUTO
STOP
<Timer function>
AUTO STOP ·········The air conditioner stops after the set time lapses. AUTO START ········The air conditioner starts after the set time lapses. AUTO OFF ············Timer is not active.
<How to operate>
1.Press POWER ON/OFF button.
2.Press “TIMER ON/OFF” button to select AUTO STOP or AUTO START.
3.Press “CLOCK/TIMER” button to set desired time.
Time setting is in 1 hour units for up to 24 hours.
Each time TIMER SET button is pressed, set time increases by 1 hour. When TIMER SET button is pressed and held, the set time increases by 1 hour every 0.5 seconds.
4. To cancel the timer operation, press POWER ON/OFF button.
This setting will stop the operation in 8hours.
With the lapse of time, time display changes in 1hour units, showing remaining time.
2-7 Test run <Before test run>
●After installing, wiring, and piping the indoor and outdoor units, check for refrigerant leakage, looseness in power supply or control wiring, and mistaken polarity.
●Use a
at least 1.0MΩ .
Attention:
Do not use the air conditioner if resistance is less than 1.0MΩ .
COOL |
|
| SWING | F |
|
|
|
| |
|
| FAN |
|
|
|
| SPEED | AUTO |
|
|
|
| RETURN | |
MODE | TIMER ON/OFF CLOCK/TIMER | FAN SPEED | AIR DISCHARGE FILTER | |
|
|
|
| AIR SWEEP CHECK |
| SET TEMP. | TIMER SET |
| TEST RUN |
REMOTE CONTROLLER
TEST RUN button
Displayed during test run
<How to operate>
1.Turn ON main breaker.
2.Press TEST RUN button twice. “TEST RUN” is displayed on remote controller.
3.Select “COOL” with MODE button to check that cool air is beginning discharged.
Select “HEAT” with MODE button to check that warm air is beginning discharged.(after a while)
4.Select LOW/HIGH with FAN SPEED button to check that the fan speed changes properly.
5.Press AIR DISCHARGE button to check auto vane operation.
6.Check outdoor fan operation.
7.Check compressor operation referring to the indoor coil temperature code displayed on the remote controller.
8.After checking, press the ON/OFF button.
·The test run works for 2 hours and stops automatically.
To cancel the test run, press ON / OFF button or TIMER ON / OFF button.