Mitsubishi Electronics PCH36GK, PCH24GK, PCH30GK OC277-69, Refrigerant Pipes, Timer Adapter

Models: PCH24GK PCH42GK PCH30GK PCH36GK

1 70
Download 70 pages 22.48 Kb
Page 69
Image 69

2. REFRIGERANT PIPES

Service Ref. : PCH24GK

Part No.

 

 

PACSK03FS

 

PACSK05FS

PACSK07FS

PACSK10FS

 

PACSK15FS

Pipe length

(ft.)

 

10

 

16

23

 

33

 

49

 

 

 

 

 

 

 

 

 

 

 

 

Pipe size O.D.(in.)

(in.)

 

 

 

Liquid:[3/8

Gas:[5/8

 

Connection method

 

 

 

 

Indoor unit: Flared

Outdoor unit: Flared

 

Service Ref. : PCH30/36GK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part No.

 

 

PACSK03FF

 

PACSK05FF

PACSK07FF

PACSK10FF

 

PACSK15FF

Pipe length

(ft.)

 

10

 

16

23

 

33

 

49

Pipe size O.D.(in.)

(in.)

 

 

 

Liquid:[1/2

Gas:[3/4

 

Connection method

 

 

 

 

Indoor unit: Flared

Outdoor unit: Flared

 

Service Ref. : PCH42GK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part No.

 

 

 

PACSK07FK

 

 

 

PACSK15FK

 

Pipe length

(ft.)

 

 

23

 

 

 

49

 

 

Pipe size O.D.(in.)

(in.)

 

 

 

Liquid:[1/2

 

Gas:[7/8

 

Connection method

 

 

 

 

Indoor unit: Flared

Outdoor unit: Flared

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1. The refrigerant pipes and the indoor unit contain a nitrogen holding charge which must be removed by evacuation. <Piping connection procedures>

See that ball valve on outdoor unit is fully shut (unit is shipped with valve shut). Remove caps from piping and unit and make flare connection promptly. Repeat for each connection, one at a time.

After all piping connections between indoor and outdoor unit have been completed, vacuum-purge air from system through the service port for the ball valve on the outdoor unit.

Note 2. The following parts are contained in optional refrigerant piping kit.

Heat insulating cover, vinyl tapes, nipples, sleeve and flange (for wall hole), connecting cables etc.

3. TIMER ADAPTER

This adapter is needed for system control and for operation via external contacts.

Part No.

PAC-SA89TA-E

4. MULTIPLE REMOTE CONTROLLER ADAPTER

This adapter is needed for remote indication (operation/check).

Part No.

PAC-SA88HA-E

OC277-69

Page 69
Image 69