Appendix -Troubleshooting

Problem

IcannotfindtheR100 WirelessGateway usingtheR100 WirelessGateway Discovery utility.

Solution

To configure the R100 through a wireless LAN card, your computer must be in the same subnet of the R100. You cannot find the R100 Wireless Gateway with a subnet different from your computer within the same gateway. You must change your computer to the same subnet as the R100s. The factory default subnet of the R100 Wireless Gateway is 192.168.1.1.

In Windows NT/2000/XP, you must log in with Administrator privileges so that all functions of the R100 Wireless Gateway Manager can function correctly. If you do not log in as a member of the Administrator group, you cannot change IP settings but can still run the Discovery utility if the original IP setting is correct.

Problem

How do I upgrade the firmware on the R100 Wireless Gateway?

Solution

Periodically, a new Flash Code is available for R100 Wireless Gateways on the Web site at:

http://www.MitsubishiElectric.com.au

Update the R100’s Flash Code using the Firmware Upgrade option on the System Setup menu of the Web manager.

Troubleshooting

88

R100 Wireless Gateway