Chapter 1 Hardware Preparation and Installation

Front/Rear Ethernet and Transition Module Options Header (J30)

A 40-pin planar header allows for selecting P2 options. Jumpers installed across Row A pins 3- 10 and Row B pins 3-10 enable front Ethernet access. Jumpers installed across Row B pins 3- 10 and Row C pins 3-10 enable P2 (rear) Gigabit Ethernet. Only when front Ethernet is enabled can the jumpers be installed across Row C and Row D on pins 1-10 to enable P2 (rear) PMC I/O. Note that all jumpers must be installed across the same two rows (all between Row A and Row B and/or Row C and Row D, or all between Row B and Row C).

The following illustration shows jumper setting options for J30. The factory default is shown where applicable:

1

11

21

31

Front Ethernet

(Default)

1

11

21

31

PMC I/O TO P2

(Default)

10

1

20

11

30

21

40

31

10

1

20

11

3021

4031

J30 Options

10

1

10

20

11

20

30

21

30

40

31

40

Rear Ethernet

 

Non-Specific Transition Module

 

 

(Default)

10

1

10

20

11

20

30

21

30

40

31

40

MVME 712M

 

MVME 761

Transition Module

 

Transition Module

 

 

4294 0604

Refer to Front/Rear Ethernet and Transition Module Options Header (J30) on page 65 for connector pin assignments.

SROM Configuration Switch (S3)

A part of the 8-position SMT switch, S3 enables/disables the MV64360 SROM initialization and all I2C EEPROM write protection.

The SROM Init switch is OFF to disable the MV64360 device initialization via the I2C SROM. The switch is ON to enable this sequence.

The SROM WP switch is OFF to enable write protection on all I2C. The switch is ON to disable the I2C EEPROM write protection.

Table 1-3. SROM Configuration Switch (S3)

POSITION

2

1

 

 

 

FUNCTION

SROM WP

SROM_INIT

 

 

 

DEFAULT (OFF)

WP

No SROM_INIT

 

 

 

8MVME6100 Installation and Use (V6100A/IH2)

Page 20
Image 20
Motorola MVME6100 manual Srom Configuration Switch S3, No Srominit