Chapter 3 MOTLoad Firmware

vmeCfg –e –rF70

Edits VMEbus Register Access Image Control Register state

Deleting VME Settings

To delete the changeable VME setting (restore default value), type the following at the firmware prompt:

vmeCfg –d –m

Deletes Master Enable state

vmeCfg –d –i(0 - 7)

Deletes selected Inbound Window state

vmeCfg –d –o(0 - 7)

Deletes selected Outbound Window state

vmeCfg –d –r184

Deletes PCI Miscellaneous Register state

vmeCfg –d –r188

Deletes Special PCI Target Image Register state

vmeCfg –d –r400

Deletes Master Control Register state

vmeCfg –d –r404

Deletes Miscellaneous Control Register state

vmeCfg –d –r40C

Deletes User AM Codes Register state

vmeCfg –d –rF70

Deletes VMEbus Register Access Image Control Register state

Restoring Default VME Settings

To restore all of the changeable VME setting back to their default settings, type the following at the firmware prompt:

vmeCfg –z

Remote Start

As described in the MOTLoad Firmware Package User’s Manual, listed in Appendix C, Related Documentation, remote start allows the user to obtain information about the target board, download code and/or data, modify memory on the target, and execute a downloaded program. These transactions occur across the VMEbus in the case of the MVME6100. MOTLoad uses one of four mailboxes in the Tsi148 VME controller as the inter-board communication address (IBCA) between the host and the target.