Troubleshooting Charts: Secure Hardware Failure

9-29

 

 

 

9.16 Secure Hardware Failure

Fail

09/10 or 09/90

Secure Hardware

Failure

Verify connections to secure module through J701

Repair

No

Connections

opens

 

 

good?

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is

Replace module

 

 

Yes

 

 

known good

with known good

 

 

 

 

 

 

module

 

 

 

 

one and retest

 

 

 

 

available?

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Synopsis

This failure relates only to secure-equipped radios and indicates a power-up self-test failure for the secure module. More specifically this failure indicates a failure in communications between the DSP and secure module. The secure module is not considered field repairable so troubleshooting is limited to verifying a problem with the module and replacing.

Typical failure modes would be:

1)Open between secure module and VOCON board at J701.

2)Failure of the SSI bus that the DSP uses to communicate with the secure module.

3)Failure to get proper supplies and grounds to J701.

Radio

functions with

known good

module?

No

Use ohmmeter to electrically verify the following signal connections to source IC:

Yes

Replace

secure module

Signal @ J701 Source

ENC_SSI_DI R403

ENC_SSI_DO R402

ENC_SSI_CLK R405

RESET_ENC R418

Verify bias of following signals:

Signal @ J701 Nominal Bias UNSW_B+ 7.5VDC+/-1.0VDC

SW_B+ 7.5VDC+/-1.0VDC

GNDGND

Connections

 

No

Repair

good?

 

connections

 

 

Yes

Verify electrical activity at the following signals at power up:

Signal @ J701 Source

ENC_SSI_DI R403 ENC_SSI_CLK R405

Replace

 

No

 

Signals

Yes

respective

 

 

source IC or

 

 

 

good?

 

VOCON board

 

 

 

 

 

Replace

secure module

MAEPF-27387-O

6881094C12-A

November 11, 2004

Page 133
Image 133