9-14

Troubleshooting Charts: Top/Side Button Test

 

 

 

9.9Top/Side Button Test

Top/Side

Button Test

Verify operation of channel knob using Button Test flowchart

Using RSS,

Yes

Button

verify problem

button is enabled

 

check OK?

for function

 

 

 

 

 

 

No

 

 

 

 

 

 

 

Synopsis

This chart relates to a failure in reading the buttons: Display, Top Side Button, One-Dot Side Button, or Two-Dot Side Button. Basic failure modes are as follows:

1)Failure in controls flex circuit

2)Bad connection

3)Defective Switch

4)Defective A/D port in GCAP II

Buttons

Enabled?

No

Use RSS to enable button

 

Using a voltmeter, measure the voltage at

 

U504 pin 3 while depressing the following

Yes

buttons:

- Display

 

 

- Top Side Button

 

- One-Dot Side Button

 

- Two-Dot Side Button

 

The voltage for each depressed

 

button should be 0 V. The voltage for

 

each button when not depressed should

 

be 2.9 V.

Replace

Yes

Levels

No

Verify physical

 

 

 

 

 

operation of

U501

 

correct?

 

 

 

buttons

 

 

 

 

 

Buttons

 

No

Replace

Housing

OK?

 

 

Assembly

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

Verify connections and control top/PTT flex circuit and repair as necessary

November 11, 2004

6881094C12-A

Page 118
Image 118
Motorola SSETM 5000 service manual Top/Side Button Test