Chapter 4 - Commands

 

 

 

 

COMMAND:

$An

VALUES:

n = 0 or 1

DEFAULT:

$A0

DESCRIPTION:

$A0 discards data during auto-reliable time period. $A1

 

buffers data during auto-reliable time period.

COMMAND:

#An

VALUES:

n = 0 thru 3

DEFAULT:

#A0

DESCRIPTION:

#A0 selects initial handshake at 33600 to 31200 to 28800

 

to 24000 to 21600 to 19200 to 16800 to 14400 to 12000 to

 

9600 to 4800 to 2400 to 1200 to 300 bps.

 

#A1 selects initial handshake at 33600 bps only.

 

#A2 selects initial handshake at 33600 to 31200 to 28800

 

to 24000 to 21600 to 19200 to 16800 to 14400 to 9600 to

 

4800 bps.

 

#A3 selects initial handshake at 2400 to 1200 to 300 bps.

COMMAND:

Bn

VALUES:

n = 0 or 1

DEFAULT:

B0

DESCRIPTION:

B0 selects V.21 for 300 bps operation.

 

B1 selects for 300 bps operation (not used on International

 

Models).

COMMAND:

&Bn

VALUES:

n = 0 or 1

DEFAULT:

&B0

DESCRIPTION:

&B0 selects normal transmit buffer size.

 

&B1 selects reduced transmit buffer size.

COMMAND:

&BSn

VALUES:

n = 0 or 1

DEFAULT:

&BS1

DESCRIPTION:

&BS0 selects maximum transmit block size of 64

 

characters.

 

&BS1 selects maximum transmit block size of 256

 

characters (MNP mode) or 128 characters (LAP-M mode).

COMMAND:

$BAn

VALUES:

n = 0 or 1

DEFAULT:

$BA0

DESCRIPTION:

$BA0 selects speed conversion on.

 

$BA1 selects speed conversion off.

COMMAND:

&Cn