Chapter 4 - Commands

4.2S-Registers

Certain Command Mode configurations are stored in memory registers called, S-Registers. The S command is used to assign a value to, and to read the current value of an S-Register.

To assign a value to an S-Register, enter the letter S, followed by the S- Register number and an equals sign (=), and then a decimal response to the message “ENTER THE NEW VALUE IN DECIMAL FORMAT”.

To read an S-Register value, enter the letter S followed by the S-Register number and a question mark (?), then hit RETURN. To verify that the S- Register value was entered correctly, enter for example, ATS8? and hit RETURN. You should receive a response of the assigned value given to that S-Register.

S0

Number of Rings Until Modem Answers

Unit:

1 ring

Range:

0-255

Default:

1

Description:

Sets the number of rings before the modem answers.

S1

Rings Which Have Occurred

Unit:

1 ring

Range:

0-255

Default:

0

Description:

Counts the number of rings that have occurred.

S2

Escape Code Character

Unit:

ASCII Character

Range:

0-127

Default:

43 (+ sign)

Description:

Defines the escape code character.

S3

 

Return Character

 

Unit:

ASCII Character

Range:

0-127

Default:

13

Description:

Defines the character recognized as Carriage Return

 

(RETURN) or “Enter”.