Chapter 4 - Commands

S4

 

Line Feed Character

 

Unit:

ASCII Character

Range:

0-127

Default:

10

Description:

Defines the character recognized as LINE FEED.

S5

 

Backspace Character

 

Unit:

ASCII Character

Range:

0-127

Default:

8

Description:

Defines the character recognized as BACKSPACE.

S6

Wait Time for Dial Tone

Unit:

1 second

Range:

2-255, 4-255**

Default:

2, 4**

Description:

Sets the time the modem waits after the RETURN key is

 

pressed before executing a dial command.

S7

Time for Carrier (Abort Timer)

Unit:

1 second

Range:

1-255, 1-45*

Default:

45

Description:

Defines the Abort Timer (lack of carrier) delay time.

S8

Pause Time for Comma

Unit:

1 second

Range:

0-255, 4-255**

Default:

2, 4**

Description:

Sets the length of the pause caused by a comma inserted

 

in a dialing commarnational and DOC units

S9

Carrier Detect Response Time

Unit:

100 mSec.

Range:

1-255

Default:

6

Description:

Sets the time delay for when the modem first detects a

 

valid incoming carrier signal and when the modem turns on

 

its Carrier Detect circuit.

** Value for International Units only