Chapter 4 - Commands

S10

Carrier Loss Disconnect Delay Time

Unit:

100 mSec.

Range:

0-255

Default:

7

Description:

Sets the time a carrier signal must be lost before the

 

modem disconnects.

S11

Tone Dialing: Tone Spacing and Duration

Unit:

1 mSec.

Range:

1-255, 80-255*

Default:

70, 80*

Description:

Sets the time duration of spacing between tone in tone-

 

dialing.

S13

Remote Configuration Escape Character

Unit:

ASCII Character

Range:

0-127

Default:

37 (% sign)

Description:

Defines the remote configuration escape character.

S16

 

Callback Attempts

 

Unit:

1 Attempt

Range:

1-255

Default:

4

Description:

S16 defines the number of attempts allowed after initial

 

passwords have been exchanged between modems.

S17

 

Changing Break Time

 

Unit:

10 mSec.

Range:

0-2.5 sec

Default:

250

Description:

S17 defines the break time (space) to local PC.

S24

PBX/CBX Disconnect Drop Time for DSR/CTS/CD

Unit:

50 mSec.

Range:

0-255

Default:

20

Description:

Defines DSR/CTS/CD dropout time. The default of 20

 

equals one second.

50