Chapter 4 - Commands

 

 

 

 

VALUES:

n = 4 or 5

DEFAULT:

&T5

DESCRIPTION:

&T4 selects Enable Response to Request for Remote

 

Digital Loopback.

 

&T5 selects Disable Response to Request for Remote

 

Digital Loopback.

COMMAND:

#Tn

VALUES:

n = 0 or 1

DEFAULT:

#T1

DESCRIPTION:

#T0 turns off Trellis Coded Modulation

 

#T1 turns on Trellis Coded Modulation

COMMAND:

Un

VALUES:

n = 0, 1, 2, or 3

DEFAULT:

n/a

DESCRIPTION:

U0 places modem in Analog Loop Originate Mode.

 

U1 places modem in Analog Loop Answer Mode.

 

U2 places modem in Remote Digital Loopback test mode.

 

U3 places modem in Local Digital Loopback Test Mode.

COMMAND:

Vn

VALUES:

n = 0 or 1

DEFAULT:

V1

DESCRIPTION:

V0 means Result Codes sent as digits(terse response).

 

V1 means Result Codes sent as words (verbose response).

COMMAND:

W

VALUES:

n/a

DEFAULT:

n/a

DESCRIPTION:

Wait for new dial-tone.

COMMAND:

&Wn

VALUES:

n = 0 or 1

DEFAULT:

&W1

DESCRIPTION:

&W0 causes modem to store its current parameters in non-

 

volatile RAM, and modem will load these for future

 

sessions instead of reading factory ROM defaults, unless

 

&F command used.

 

&W1 causes modem to not store parameters.

COMMAND:

Xn

VALUES:

n = 0, 1, 2, 3 or 4

41

Page 41
Image 41
Multi-Tech Systems MT2834BR, MT2834BLR manual = 4 or