| Chapter 4 - Commands |
|
|
|
|
VALUES: | n = 0 or 1 |
DEFAULT: | %DP0 |
DESCRIPTION: | %DP0 selects do not read Line Probe Information from |
| DSP during handshaking. |
| %DP1 selects read Line Probe Information from DSP |
| during handshaking. |
COMMAND: | En |
VALUES: | n = 0 or 1 |
DEFAULT: | E1 |
DESCRIPTION: | E0 selects do not echo Command mode characters. |
| E1 selects do echo Command mode characters. |
COMMAND: | &En |
VALUES: | n = 0 thru 15 |
DEFAULT: | &E1, &E4, &E6, &E10, &E13, &E15 |
DESCRIPTION: | &E0 selects no error correction. |
| &E1 selects V.42 |
| &E2 selects V.42 Reliable Mode. |
| &E3 selects no |
| &E4 selects CTS |
| &E5 selects Xon/Xoff |
| &E6 selects Xon/Xoff not passed through. |
| &E7 selects Xon/Xoff passed through. |
| &E8 selects Enq/Ack pacing off. |
| &E9 selects Enq/Ack pacing on. |
| &E10 selects Normal Mode flow control off. |
| &E11 selects Normal Mode flow control on. |
| &E12 selects Pacing off. |
| &E13 selects Pacing on. |
| E14 selects data compression disabled. |
| &E15 selects data compression enabled. |
COMMAND: | %En |
VALUES: | n=0 thru 5 |
DEFAULT: | %E1 |
DESCRIPTION: | %E0 = Modem Won’t Escape. |
| %E1 = +++ Method (default setting). |
| %E2 = Break Method. |
| %E3 = Either +++ or Break Method. |
| %E4 = No "OK" Response to +++ |
| %E5 = "OK" Response to +++ |
COMMAND: | #Fn |