Chapter 5 – AT Commands, S-Registers, and Result Codes

Command:

A

Answer

Description:

 

The modem will go off-hook and attempt to answer an incoming call if

 

 

correct conditions are met. Upon successful completion of answer

 

 

handshake, the modem will go on-line in answer mode. This command

 

 

may be affected by the state of Line Current Sense, if enabled. (Most

 

 

countries do not require Line Current Sense.) Operation is also dependent

 

 

upon +FCLASS command and country-specific requirements.

 

 

If +FCLASS=0 is selected, the modem will enter the Connect state after

 

 

exchanging carrier with the remote modem. If no carrier is detected within

 

 

a period specified in register S7, the modem hangs up. Any character

 

 

entered during the connect sequence will abort the connection attempt.

 

 

If +FCLASS=1, 1.0, or 2 is selected, the modem will go off-hook in V.21

 

 

answer mode. It will generate the V.21 2100 Hz answer tone for 3 ± 0.5

 

 

seconds and, following a delay of 70 ms, will proceed as if the +FTH=3

 

 

command were issued. At any stage up to (but excluding) the +FTH=3

 

 

command state, any character will abort the communication. (See the

 

 

description of the +FTH command for details.)

Command:

H

Disconnect (Hang-Up)

Description:

 

Initiates a hang up sequence. This command may not be available for

 

 

some countries due to PTT restrictions.

Default:

 

None

 

Defined Values:

 

H0

The modem will release the line if the modem is currently on-line,

 

 

 

and will terminate any test (AT&T) that is in progress. Country

 

 

 

specific, modulation specific, and error correction protocol specific

 

 

 

(S38) processing is handled outside of the H0 command.

 

 

H1

If on-hook, the modem will go off-hook and enter command mode.

 

 

 

For US models, the modem will remain off-hook. For W-class

 

 

 

models, the modem will return on-hook after a period of time

 

 

 

determined by S7.

Result Codes:

 

OK

 

 

 

Otherwise ERROR

Command:

O

Return to Online Data Mode

Description:

 

Determines how the modem will enter the online data mode. If in the online

 

 

command mode, the modem enters the online data mode with or without a

 

 

retrain. If in the off-line command mode (no connection), the modem

 

 

reports ERROR.

Default:

 

None

 

Defined Values:

 

O0

Enters on-line data mode without a retrain.

 

 

 

Handling is determined by the Call Establishment task. Generally, if

 

 

 

a connection exists, this command connects the DTE back to the

 

 

 

remote modem after an escape (+++).

 

 

O1

Enters on-line data mode with a retrain before returning to on-line

 

 

 

data mode.

 

 

O2

Fast retrain without speed change (used for diagnostic purpose

 

 

 

only).

 

 

O3

Renegotiate rate without speed change (used for diagnostic purpose

 

 

 

only.

 

 

O4

Renegotiate rate down one speed (used for diagnostic purpose

 

 

 

only).

 

 

O5

Renegotiate rate up one speed (used for diagnostic purpose only).

Result Codes:

 

OK

 

 

 

Otherwise ERROR (or if not connected)