Chapter 5 – AT Commands, S-Registers, and Result Codes

Command:

&C

RLSD (DCD) Option

Description:

 

The modem controls the RLSD output in accordance with the parameter

 

 

supplied. The parameter value, if valid, is written to S21 bit 5.

Default:

 

1

 

Defined Values:

 

0

RLSD remains ON at all times.

 

 

1

RLSD follows the state of the carrier.

Result Codes:

 

OK

 

 

 

Otherwise ERROR

Command:

&D

DTR Option

Description:

 

Interprets the ON to OFF transition of the DTR signal from the DTE in

 

 

accordance with the parameter supplied. The parameter value, if valid, is

 

 

written to S21 bits 3 and 4. Also, see S25.

Default:

 

2

 

Defined Values:

 

&D0

DTR drop is interpreted according to the current &Q setting as

 

 

 

follows:

 

 

 

&Q0, &Q5, &Q6: DTR is ignored (assumed ON). Allows operation

 

 

 

with DTEs, which do not provide DTR.

 

 

 

Q1 DTR drop causes the modem to hang up. Auto-answer is not

 

 

 

affected.

 

 

 

&Q2, &Q3 DTR drop causes the modem to hang up. Auto-answer is

 

 

 

inhibited.

 

 

&D1

DTR drop is interpreted according to the current &Q setting as

 

 

 

follows:

 

 

 

&Q0, &Q1, &Q5, &Q6 DTR drop is interpreted by the modem as if

 

 

 

the asynchronous escape sequence had been entered. The modem

 

 

 

returns to asynchronous Command State without disconnecting.

 

 

 

&Q2, &Q3 DTR causes the modem to hang up Auto-answer is

 

 

 

inhibited.

 

 

&D2

DTR drop is interpreted according to the current &Q setting as

 

 

 

follows:

 

 

 

&Q0 through &Q6 drop caused the modem to hang up. Auto-answer

 

 

 

is inhibited.

 

 

&D3

DTR drop is interpreted according to the current &Q setting as

 

 

 

follows:

 

 

 

&Q0, &Q1, &Q5, &Q6 DTR drop causes the modem to perform a soft

 

 

 

reset as if the Z command were received. The &Y setting determines

 

 

 

which profile is loaded.

 

 

 

&Q2, &Q3 DTR drop causes the modem to hang up. Auto-answer is

 

 

 

inhibited.

 

 

 

If &Q5, &Q6, +FCLASS=1 or +FCLASS=2 is in effect, the action

 

 

 

taken is the same as for &Q0.

Command:

&K

Flow Control

Description:

 

Defines the DTE/DCE (terminal/modem) flow control mechanism. The

 

 

parameter value, if valid, is written to S39 bits 0, 1, and 2.

Default:

 

3 (for data modem modes)

Defined Values:

 

0

Disables flow control.

 

 

3

Enables RTS/CTS flow control.

 

 

4

Enables XON/XOFF flow control.

 

 

5

Enables transparent XON/XOFF flow control.

 

 

Note: Upon reset, both RTS/CTS and XON/XOFF flow control is enabled

 

 

 

for fax modem and voice modes.

Result Codes:

 

OK

 

 

 

Otherwise ERROR

Multi-Tech Systems, Inc. SocketModem MT5600SMI Developer’s Guide

38

Page 38
Image 38
Multi-Tech Systems MT5600SMI-P32, MT5600SMI-XL34 manual Command Rlsd DCD Option, Command DTR Option, Command Flow Control