Chapter 5 – AT Commands, S-Registers, and Result Codes

Example Modem Response and Usage

Example #UD commend response are shown in Table 5-13.

Table 5-13. Completed Data Call, with some errors and rate retrain during the call

Modem Response Line

Description

DIAG <2A4D3263 0=09>

This is version 0.9

DIAG <2A4D3263 1=06 2=0 3=0>

Data Answer signal detected; Data only;

 

Character async

DIAG <2A4D3263 5=”C14513902A” 6=”A145”>

V.8 Call Menu indicates:

 

V.8 Joint Menu selects:

DIAG <2A4D3263 10=1F 11=0C 12=52>

Receive level = -31 dBm; transmit level = -12

 

dBm; noise level = -82 dBm

DIAG <2A4D3263 14=03 15=05 16=10>

Far end echo delay in milliseconds; Far end

 

echo loss in dB; Near end echo loss = 16 dB

DIAG <2A4D3263 20=C 22=780 24=0C80 26=79E0>

Transmitter: V.34 training completed;

 

V.34 carrier frequency = 1920; V.34

 

symbol rate = 3200; initial transmit rate is

 

31200 bit/s

DIAG <2A4D3263 21=D 25=1F40 27=DAC0>

Receiver: V.90 training completed; V.90

 

symbol rate = 8000; initial receive rate is

 

56000 bit/s

DIAG <2A4D3263 30=00 31=03 32=01 33=01>

No carrier loss events, 3 carrier rate

 

renegotiations attempted; 1 carrier

 

retrain requested; 1 carrier retrain

 

granted

DIAG <2A4D3263 34=7080 35=CB20>

Final transmit rate is 28800 bit/s; final

 

receive rate is 52000 bit/s

DIAG <2A4D3263 40=1 41=100>

LAPM negotiation completed; frame size =

 

256

DIAG <2A4D3263 42=0 43=0>

No error control timeout or link NAKs

DIAG <2A4D3263 44=1 45=400>

V.42bis data compression used;

 

dictionary size = 1024

DIAG <2A4D3263 50=2 51=2>

Hardware transmit and receive flow control

DIAG <2A4D3263 52=343CC 54=0>

213964 DTE characters transmitted, w/o

 

underrun

DIAG <2A4D3263 53=7230E6 55=47>

7483622 DTE characters received, 71

 

characters lost due to receive data overrun

DIAG <2A4D3263 56=29D 58=0001>

597 (decimal) frames transmitted, with 1

 

frame error

DIAG <2A4D3263 58=2A4B 59=0004>

10827 (decimal) frames received, with 4

 

frame errors

DIAG <2A4D3263 60=51>

Local PC initiated hangup