Chapter 5 – AT Commands, S-Registers, and Result Codes

Register

Unit

Range

Default

Description

 

S27

 

 

73 (49Ah)

General Bit-Mapped Options Status: Indicates the status of

 

 

 

 

command options.

 

 

 

 

Default:

73 (49h) (01001001b)

 

 

 

 

Bits 0, 1, 3

Synchronous/asynchronous selection (&Mn/&Qn)

 

 

 

 

 

3 1 0

 

 

 

 

 

 

0 0 0

&M0 or &Q0

 

 

 

 

 

0 0 1

&M1 or &Q1

 

 

 

 

 

0 1 0

&M2 or &Q2

 

 

 

 

 

0 1 1

&M3 or &Q3

 

 

 

 

 

1 0 0

Reserved

 

 

 

 

 

1 0 1

&Q5 (Default.)

 

 

 

 

 

1 1 0

&Q6

 

 

 

 

Bit 2

Leased line control (&Ln)

 

 

 

 

 

0 =

Dial up line (&L0) (Default.)

 

 

 

 

Bits 4 - 5

Internal clock select (&Xn)

 

 

 

 

 

0 =

Internal clock (&X0) (Default.)

 

 

 

 

 

1 =

External clock (&X1)

 

 

 

 

 

2 =

Slave clock (&X2)

 

 

 

 

Bit 6 CCITT/Bell mode select (Bn)

 

 

 

 

 

0 =

CCITT mode (B0)

 

 

 

 

 

1 =

Bell mode (B1) (Default.)

 

 

 

 

Bit 7 - Reserved

S28

 

 

0

General Bit-Mapped Options Status: Indicates bit mapped options

 

 

 

 

status.

 

 

 

 

 

Default:

0

 

 

 

 

Bits 0 - 1

Reserved

 

 

 

 

Bit

2 Reserved (always 0).

 

 

 

 

Bits 3 - 4

Pulse dialing (&Pn)

 

 

 

 

 

0 = 39%-61% make/break ratio at 10 pulses per second (&P0)

 

 

 

 

 

1 = 33%-67% make/break ratio at 10 pulses per second (&P1)

 

 

 

 

 

2 = 39%-61% make/break ratio at 20 pulses per second (&P2)

 

 

 

 

 

3 = 33%-67% make/break ratio at 20 pulses per second (&P3)

 

 

 

 

Bit 5-7Reserved

S29

10 ms

0–255

70

Flash Dial Modifier Timer: Sets the length of time, in units of 10 ms,

 

 

 

 

that the modem will go on-hook when it encounters the flash (!) dial

 

 

 

 

modifier in the dial string. S29 is a country dependent parameter. The

 

 

 

 

S29 value cannot be changed using S29=XX. Default: 70 (700 ms)

 

 

 

 

for U.S.

 

S30

10 s

0–255

0

Disconnect Inactivity Timer: Sets the length of time, in tens of

 

 

 

 

seconds, that the modem will stay online before disconnecting when

 

 

 

 

no data is sent or received. In error-correction mode, any data

 

 

 

 

transmitted or received will reset the timer. In other modes, any data

 

 

 

 

transmitted will reset the timer. The timer is inoperative in

 

 

 

 

synchronous mode.

S31

 

 

192 (C0h) General Bit-Mapped Options Status: Indicates bit mapped options

 

 

 

 

status.

 

 

 

 

 

Default:

192 (C0h) (11000000b)

 

 

 

 

Bit 0 Single line connect message enable/disable (\Vn)

 

 

 

 

 

0 =

Messages controlled by S95, Wn and Vn (\V0)

 

 

 

 

 

(Default.)

 

 

 

 

 

1 =

Single line connect message (\V1)

 

 

 

 

Bit 1

Reserved (0)

 

 

 

 

Bits 2-3

Error correction progress messages (Wn)

 

 

 

 

 

0 =

DTE speed only (W0) (Default.)

 

 

 

 

 

1 =

Full reporting (W1)

 

 

 

 

 

2 =

DCE (line) speed only (W2)

 

 

 

 

Bits 4-5

Caller ID (+VCID)

 

 

 

 

 

0 =

Caller ID disabled (+VCID=0) (Default.)

 

 

 

 

 

1 =

Short (formatted) Caller ID enabled (+VCID=1)

 

 

 

 

 

2 =

Long (unformatted) Caller ID enabled (+VCID=2)

 

 

 

 

Bits 6-7

Reserved (Default = 11b)

Multi-Tech Systems, Inc. SocketModem MT5600SMI Developer’s Guide

78

Page 78
Image 78
Multi-Tech Systems MT5600SMI-XL34, MT5600SMI-P92, MT5600SMI-PL92, MT5600SMI-92 Register Unit Range Default Description S27