Chapter 5 – AT Commands, S-Registers, and Result Codes

Command: &V1

Display Last Connection Statistics

Description:

Displays the last connection statistics in the following format (shown with

 

typical results):

 

 

TERMINATION REASON

LOCAL REQUEST

 

LAST TX rate

26400 BPS

 

HIGHEST TX rate

26400 BPS

 

LAST RX rate.

49333 BPS

 

HIGHEST RX rate

49333 BPS

 

PROTOCOL

LAPM

 

COMPRESSION

V42Bis

 

Line QUALITY

038

 

Rx LEVEL

015

 

Highest Rx State

67

 

Highest TX State

67

 

EQM Sum

00B4

 

Min Distance

0000

 

RBS Pattern

00

 

Rate Drop

00

 

Digital Loss

2000

 

Local Rtrn Count

00

 

Remote Rtrn Count

00

 

Flex 9481814347C4

 

RBS Pattern: Shows which bits are being robbed in the least significant 6 bytes, e.g., 03 indicates 2 robbed bits in bit positions 0 and 1.

Digital Loss: Shows if a pad was encountered and if so, what was the digital loss. 2000 means 0dB.

Flex: Shows V.8bis information as follows:

First byte: Octet 13 (second byte of manufacturer id, 94 = 56K)

Second byte: Octet 14 (Licensee code: 81 = Conexant)

Third byte: Octet 15 (manufacturer's product capabilities)

Fourth byte: Octet 16 (56K version number)

Fifth byte: Octet 17 (Conexant pump code version number)

Sixth byte: Octet 18 (x-law and controller version number)

Bit 6 Forced/Not forced A-Law/µ-Law

0= Forced A-Law/µ-Law.

1= Not forced A-Law/µ-Law.

Bit 5 Select A-Law or µ-Law

0= Select A-Law.

1= Select µ-Law.

Bit 4:0 Controller version

Multi-Tech Systems, Inc. SocketModem MT5600SMI Developer’s Guide