Revised
9000 Series Industrial Gigabit Ethernet Switch User Manual
Installation Guide
Industrial Gigabit Ethernet Switch Installation Guide
page 3 of
page 4 of
Server-IpAddress
File-Name
Server-IpAddress
File-Name
page 6 of
Industrial Gigabit Ethernet Switch Installation Guide 9000 Series
PRODUCT FEATURES
MANAGEMENT FEATURES
MODULE / SLOT OPTIONS
Safety Warnings
GENERAL SAFETY
Contact Information
Email N-TRONSupport@n-tron.com
9000 Series Hazardous Location Installation Requirements
ENVIRONMENTAL SAFETY
ELECTRICAL SAFETY
INSTALLATION
PACKAGE CONTENTS
CLEANING
UNPACKING
Replacing a CPU Module
page 11 of
DIN-Rail Mounting
page 12 of
Panel Mount Mounting
page 13 of
FRONT PANEL
APPLYING POWER Side View
N-TRON SWITCH GROUNDING TECHNIQUES
page 16 of
CAT5 CABLE SPECIFICATIONS
page 17 of
page 18 of
CONNECTING THE UNIT
SERIAL INTERFACE
page 19 of
Serial Cable
HyperTerminal
Overview of Advanced Features Mode of Operation
Half Duplex
Full Duplex
Auto Negotiation
Virtual LAN
Rapid Spanning Tree Protocol
SNMP Traps
page 21 of
page 22 of
IGMP Snooping
N-Ring
FCC STATEMENT
TROUBLESHOOTING
SUPPORT
Default
Web Management
Web Software Configuration
User Name admin Password admin
Web Management - Home
page 25 of
Web Management - Menu Structure
page 26 of
Administration - System
IP Address Subnet Mask Default Gateway MAC Address System Up Time
IP Address Subnet Mask Default Gateway
Name Contact Information Location
Administration - SNMP
page 28 of
Administration - Slots
page 29 of
Ports - Configuration
Port Number Port Name Admin Status Link Status Auto Negotiation State
Port Speed Duplex Mode Flow Control State Back Pressure State
Priority State Priority Level RSTP State PVID
Revised
page 31 of
State of Priority Priority Level PVID
Ports - Configuration, Continued…
Admin Status Speed and Duplex Flow Control Back Pressure
Ports - Security
page 33 of
Ports - Intrusion Log
page 34 of
Ports - Mirroring
page 35 of
Ports - Trunking
Ports - Trunking, Continued…
page 37 of
Statistics - Port Statistics
page 38 of
Statistics - Ports Utilization
page 39 of
VLAN - Ingress Filter
page 40 of
See VLAN Configuration Examples on Page
VLAN - Port Based
page 42 of
VLAN - Port Based, Continued…
See VLAN Configuration Examples on Page
page 43 of
See VLAN Configuration Examples on Page
VLAN - Port Based, Continued…
Bridging - Aging Time
page 44 of
Bridging - Unicast Addresses
page 45 of
Bridging - Unicast Addresses, Continued…
page 46 of
Bridging - Multicast Addresses
page 47 of
Bridging - Multicast Addresses, Continued…
page 48 of
2. N-Ring Manager cannot have RSTP enabled
RSTP - RSTP Configuration
1. Trunking must be disabled in order to use RSTP
RSTP - RSTP Configuration, Continued…
page 50 of
RSTP - RSTP Configuration, Continued…
page 51 of
RSTP - RSTP Configuration, Continued…
page 52 of
IGMP - Configuration
page 53 of
IGMP - Show Group and Show Router
page 54 of
IGMP - RFilter
Modifying rfilter port settings
page 56 of
N-Ring - Configuration
“Switch is currently using N-Ring Aging Time = 20 Seconds”
N-Ring Configuration continued
The “N-Ring Mode” is one of three, as below
N-Ring Configuration continued
page 59 of
N-Ring Configuration continued
page 60 of
N-Ring - Status
N-Ring Status View
Switch is an N-Ring Manager, using N-Ring Aging Time = 20 Seconds
N-Ring OK
Refresh every
N-Ring Status View
N-Ring Status View
N-Ring Status View
0007af00b140
page 64 of
NView - Configuration
page 65 of
NView - Ports
page 66 of
NView - Ports, Continued…
page 67 of
EventLog - Log Statistics
page 68 of
EventLog - Show Events
page 69 of
Firmware/Config - TFTP
page 70 of
Firmware/Config - FTP
page 71 of
Support - Web Site and E-mail
page 72 of
BPCL - Broadcast Packet Count Limit Configuration
page 73 of
User Mgmt - Adding Users
page 74 of
User Mgmt - Removing Users
page 75 of
Logical View
page 76 of
Configuration - Save or Reset
page 77 of
Help - Overview
page 78 of
Help - Administration
or user can see some the left side of the web
Help - Ports
page 80 of
Help - Statistics
page 81 of
Help - VLAN
page 82 of
Help - BPCL
page 83 of
Help - IGMP
page 84 of
Help - Bridging
page 85 of
Help - RSTP
page 86 of
Help - Event Log
page 87 of
Help - Firmware/Config
page 88 of
Help - Logical View
page 89 of
Help - User Mgmt
page 90 of
Help - N-View
page 91 of
Help - N-Ring
page 92 of
Help - Others
page 93 of
CLI Commands
command ?
The above command displays all the available commands
Clear
History
The above command displays previously entered commands
Logout
here comes the usage of “!” command
The above command will execute the second command, which is
The above command will execute the latest command in the history list
available in history list
As shown above the command whoaim was entered instead of whoami
To edit the already entered command do as follows
Now we can edit the command at the command prompt
Whoami
System Configuration Commands
Set Mode IP config
Set IP/Subnet/Gateway Addresses of the system
system set ip IP-address subnet gateway
Get Gateway Address of the System
Get Mac Address of the System
Get Netmask of the System
Get System Contact
Set System Location
Location-of-the-system
Get System Uptime
Get Number of Ports present in the System
Show all configuration parameters
Set SNMP Set Community name
Set SNMP Trap Community name
page 101 of
page 102 of
Show all configuration parameters related to SNMP manager
System Restart
User Management Commands
Modify a User’s Access Permissions
Modify a User’s Password
Show System Users
Remove a System User
system remove user
system remove user username
username
Image Loader Commands
TFTP Commands
Set the TFTP configuration parameter
Show TFTP configuration parameters
FTP Commands
Set Password
Set Username
eg.1
Display FTP related configuration parameters
Perform the configuration file transfer action
eg.1
eg.2
Port Manager Commands
Get admin status of the port
Set admin status of a port
port set adminstatus port-noenable disable
Show port statistics
Get total number of good frames received
eg.1
Get port speed
port set lockstate port-no enable disable
Set the port duplex mode
port set duplexmode port-no full half
Set the Lockstate of a given port
port set autonego port-noenable disable
port set prioritystate enable disableport-no
port set flowcontrol port-noenable disable
Set Auto-negotiation State
port set backpressure port-noenable disable
Show Configuration
Set Backpressure
Set Intruderstate
Show Link Utilization
Get Flow Control
Get Name
Get State Of Priority
Get STP Status
Get Back Pressure
Get PVID
Clear Counters
Trunk related commands
Enable or Disable Trunking
Modify Trunk
Create Trunk
N-TRON/Admin#1 trunk delete
N-TRON/Admin#1 trunk show
DISABLE
Delete Trunk
Mirroring related commands
Set Mirror config
Enable or Disable Port Mirroring
Show Mirror config
VLAN Related Commands
Show List of Configured VLANs
Add VLAN Entry
vlan add vlan id mgmt port
vlan set mgmtvlan vlan-id enabledisable
Modify an existing VLAN
Delete VLAN
Set VLAN as a management VLAN
Set VLAN to defaults
Set VLAN Ingress Filter
Get VLAN Ingress Filter
Get VLAN info
Eventlog Related Commands
Get Eventlog count
Get Eventlog level
Get Eventlog size
N-TRON/Admin#1 eventlog show events
Show Eventlog events
Bridging Related Commands
Add Multicast MAC Address
Delete Multicast MAC Address
Add a Unicast MAC Address
Display List of Configured Static MAC Addresses
Set Aging Time
Display Current Aging Time
Display Mac Address by port
N-TRON/Admin#1 bridge show maccount
Display Mac count
IGMP Related Commands
Enable IGMP
Disable IGMP
Show IGMP config
Show IGMP router
Set IGMP query mode
Set IGMP router port
Set IGMP router mode
page 128 of
Show IGMP rfilter mode
Set IGMP rfilter mode
N-Ring Related Commands
N-Ring get webfault
N-Ring set webfault
N-Ring get agingtime
n-ring set mode managerautomemberdisable -rp AE -vlanid
N-Ring set interval
N-Ring get mode
N-Ring set mode
N-Ring show switch
n-ring show switch
n-ring show switch MAC ADDRESS
N-Ring show status
N-TRON/Admin#10n-ring/set n-ring set keepalive
Keep-Alive Timeout set to
N-TRON/Admin#10n-ring/get n-ring get keepalive
Keep-Alive Timeout is
Configuration Related Commands
Save Configuration
Load Default Configuration
Configuration Upload
Rapid Spanning Tree Protocol Related Commands
Set RSTP Admin Edge
rstp set adminedge vlan id port no status
Get RSTP Admin Edge
Set RSTP Bridge Admin Status
rstp set bridgeadminstatus vlan id bridge adminstatus
Get RSTP Bridge Admin Status
Set RSTP Bridge Forward Delay
N-TRON/Admin#1 rstp set bridgehellotime 1
N-TRON/Admin#2 rstp set bridgehellotime 2
N-TRON/Admin#1 rstp get bridge hellotime
N-TRON/Admin#2 rstp get bridge hellotime
Set RSTP Bridge Priority
rstp set bridgepriority vlan-id bridge priority
Get RSTP Bridge Priority
Set RSTP Port Path Cost
Get RSTP Port Priority
Set RSTP Port Priority
rstp set portpriority vlan-id port no port priority
Broadcast Packet Count Limit Commands
Get the Broadcast Packet Count Limit for one port
Get the Broadcast Packet Count Limit for all ports
Set the Broadcast Packet Count Limit
Example 2 - Basic understanding of tagged VLANs Admit - Tagged Only
VLAN Configuration Examples
Example 1 - Basic understanding of port based VLANs
VLAN Configuration View
Ports Configuration View
VLAN Configuration View
Ports Configuration View
Example 5 - Basic understanding of Overlapping VLANs
Example 6 - Basic understanding of VLANs with Multicast Filtering
KEY SPECIFICATIONS
Switch Properties
Connectors
Recommended Wiring Clearance
100 Mb Fiber Transceiver Characteristics
Gigabit Fiber Transceiver Characteristics
Regulatory Approvals
Conducted Low Frequency IEC60533
N-TRON Limited Warranty
page 145 of