Chapter4 SignalConnections
©NationalInstruments Corporation 4-37 6023E/6024E/6025EUser Manual
deassertedtoff after the last conversion in the scan is initiated. This output is
setto high impedance at startup.
Figures 4-25 and 4-26 showthe input and outp ut timing requirements for
the STARTSCANsignal.
Figure4-25. STARTSCANInput Signal Timing
Figure4-26. STARTSCANOutput Signal Timing
The CONVERT*pulses are masked off until the device generates the
STARTSCANsignal.If you are using internally g enerated conversions,the
firstCONVERT* appears when the onboard sample interval counter
reacheszero. If you select an external CONVERT*, the first external pulse
afterSTARTSCAN generates a conversion. Separate theSTARTSCAN
pulses byat least one scan period.
Rising-Edge
Polarity
Falling-Edge
Polarity
tw
tw=10 ns minimum
tw=50-100 ns
a. Start of Scan
toff
toff= 10 ns minimum
StartPulse
CONVERT*
STARTSCAN
STARTSCAN
b. Scan in Progress, Two Conversions per Scan
tw