4-22 The table below lists how selections for "AC LINK" determine the power status of the server when the power supply to the server restarts.
Parameter
State before powered off Stay Off Last State Power On
In service Off On On
Out of service (DC power: Off) Off Off On
Forced shutdown * Off Off On
* Pressing the POWER switch for over four seconds shuts down the power to the server.
Thermal Sensor Select "Thermal Sensor" on the System Hardware menu and press Enter to display the following screen. See the table below for setup options on the screen. Option Parameter Description Your Setting
Thermal
Sensor [Enabled]
Disabled Enable or disable the thermal sensor
monitoring feature.
Upper Limit 7 - [48] - 80 Specify the upper limit temperature for
boot-up restriction in Celsius. Use + and/or -
keys to specify a value by adding a number
greater than 7 to the value specified for
Lower Limit.
Lower Limit 0 - [5] - 73 Specify the lower limit temperature for
boot-up restriction in Celsius. Do not specify
4 degrees or lower. Use + and/or - keys to
specify a value by deducting a number
greater than 7 to the value specified for
Upper Limit.
[ ]: Factory-set
Thermal Sensor:
Upper Limit:
Lower Limit:
Determines if BIOS will
disable boot, if the
temperature is not
within safe range.
Item Specific HelpThermal Sensor
[Enabled]
[48]
[5]
System Hardware
Phoenix BIOS Setup Utility
F1 Help -/+ Change Values F9 Setup Defaults
F10 Save Changes & ExitSub-MenuEnter Select
Esc Exit Select Item