5-46
Procedure in the ft server utility
72. Enable “Auto module start” and “Auto firmware update”.
See “Setup of System Operation” in this chapter for the procedure to enable.
73. Store the image data of the firmware for update in the NEC Express5800/ft series.
Save it in the /etc directory under the name “BIOS.ROM”.
74. On the main window of the ft server utility, select the target component.
The screen of the target component appears.
75. Check the current state of the target component with the LEDs. If the component is
running, stop the component.
76. Click [Update] on [Firmware].
The [Firmware Update] screen appears.
77. Select [File Path Update] and then click [Execute].
The firmware update will be performed. After the firmware update has completed, the
target component automatically starts and the other stops.
IMPORTANT:
If “Auto firmware update” is disabled, the target component will not start and the
firmware update will not complete. In such case, perform the firmware update again
after enabling “Auto firmware update”.
78. The other component will start automatically and the firmware will be updated
automatically.
IMPORTANT:
If “Auto module start” is disabled, the target component will not start automatically. In
such case, start the component manually. The firmware will be updated automatically.