7-12
STATUS LED
Indication Color State Suspected
module Explanation Procedure
CPU2 removed Green Blink CPU module #2 The CPU module has come
off. Dismount and remount
the PCI module. If not
solved by the above,
contact your sales
agent.
CPU2 Temp Alm 00 Amber Blink CPU module #2 Temperature alarm (lower
limit)
CPU2 Temp Alm 02 Amber Lit CPU module #2 Fatal temperature alarm (lower
limit)
CPU2 Temp Alm 07 Amber Blink CPU module #2 Temperature alarm (upper
limit)
CPU2 Temp Alm 09 Amber Lit CPU module #2 Fatal temperature alarm
(upper limit)
Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales
agent.
CPU2 VccpAlm 00 Amber Blink CPU module #2 CPU operating voltage alarm
(lower limit) (VCCP)
CPU2 VccpAlm 02 Amber Lit CPU module #2 Fatal CPU operating voltage
alarm (lower limit) (VCCP)
CPU2 VccpAlm 07 Amber Blink CPU module #2 CPU operating voltage alarm
(upper limit) (VCCP)
CPU2 VccpAlm 09 Amber Lit CPU module #2 Fatal CPU operating voltage
alarm (upper limit) (VCCP)
CPU2 VttAlm 00 Amber Blink CPU module #2 1.25-V power voltage alarm
(lower limit)
CPU2 VttAlm 02 Amber Lit CPU module #2 Fatal 1.25-V power voltage
alarm (lower limit)
CPU2 VttAlm 07 Amber Blink CPU module #2 1.25-V power voltage alarm
(upper limit)
CPU2 VttAlm 09 Amber Lit CPU module #2 Fatal 1.25-V power voltage
alarm (upper limit)
Contact your sales
agent.
CPU20 TempAlm
00 Amber Blink CPU module #2 CPU#1 temperature alarm
(lower limit)
CPU20 TempAlm
02 Amber Lit CPU module #2 Fatal CPU#1 temperature
alarm (lower limit)
CPU20 TempAlm
07 Amber Blink CPU module #2 CPU#1 temperature alarm
(upper limit)
CPU20 TempAlm
09 Amber Lit CPU module #2 Fatal CPU#1 temperature
alarm (upper limit)
CPU21 TempAlm
00 Amber Blink CPU module #2 CPU#2 temperature alarm
(lower limit)
CPU21 TempAlm
02 Amber Lit CPU module #2 Fatal CPU#2 temperature
alarm (lower limit)
CPU21 TempAlm
07 Amber Blink CPU module #2 CPU#2 temperature alarm
(upper limit)
CPU21 TempAlm
09 Amber Lit CPU module #2 Fatal CPU#2 temperature
alarm (upper limit)
Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales
agent.
= D =
DUMP Request! Off - DUMP switch request Contact your sales
agent.
= F =
FRB Processing Off - During POST execution or OS
start processing The server is operating
normally.