2-17
LED indications
Primary Secondary Description Action
Detected a fatal
temperature error. If LCD displays some error message,
refer to the error message list (see
Chapter 7).
Check if dust is accumulated on internal
fans and confirm that the fan cables are
connected firmly. If the message does
not disappear, contact your sales agent.
Amber Off
Detected a fatal voltage
error. Contact your sales agent.
Detected a temperature
error to be warned. If LCD displays some error message,
refer to the error message list (see
Chapter 7).
Check if dust is accumulated on internal
fans and confirm that the fan cables are
connected firmly. If the message does
not disappear, contact your sales agent.
Detected a voltage error to
be warned.
Detected a device defect.
Contact your sales agent.
Amber
(blinking
every 1
second)
Off
Detected a fan alarm. If LCD displays some error message,
refer to the error message list (see
Chapter 7).
Check if dust is accumulated on internal
fans, and confirm that the fan cables are
connected firmly. If the message does
not disappear, contact your sales agent.
BMC is being dumped. Wait for a while; it will go off soon.
PCI module may be
connected incorrectly. Check if PCI module is connected
correctly. Look for loose screws.
Red Off
BMC may be out of order. BMC firmware may need
reprogramming. Contact your sales
agent.
BMC is being dumped. Wait for a while. After a while, the BMC
status LED on the secondary will blink.
PCI module may be
connected incorrectly. Check if PCI module is connected
correctly. Look for loose screws.
ANY*1 Red
BMC may be out of order. BMC firmware may need to be
rewritten. Contact your sales agent.
ANY*1 Red
(blinking
every 0.5
second)
Transfers data being
synchronized after a PCI
module is replaced (this is
not an error).
Do not remove either of the PCI
modules or control the AC/DC power
until the LED stops blinking.
ANY*1 Red
(blinking
every 1
second)
The revision of BMC
firmware does not match. Contact your sales agent.