7-16
On-screen error message Cause Action
0B29 Unsupported Processor
detected on Processor 2 The processor (CPU) not
supported by this server is
installed in Processor 2.
Install the CPU appropriate to
the server.
0B30 CPU FAN #1 Alarm
occurred
0B31 CPU FAN #2 Alarm
occurred
• Dusts are clogged in fan.
• Fan is faulty.
• CPU module board is
faulty.
• Replace the fan.
• Replace the CPU module
board.
• Connect fan cable
properly.
0B32 CPU FAN #3 Alarm
occurred
• Dusts are clogged in fan.
• Fan is faulty.
• CPU module board is
faulty.
• Replace the fan.
• Replace the CPU module
board.
• Connect fan cable
properly.
0B40 Invalid System
Configuration Data
• Configuration error in
SETUP.
• CPU/PCI module board is
faulty.
• Reset the setting by
selecting [Yes] at [Reset
Configuration Data]
• Replace the CPU/PCI
module board.
0B41 System Configuration
Data Read error
• Configuration error in
SETUP.
• CPU/PCI module board is
faulty.
• Reset the setting by
selecting [Yes] at [Reset
Configuration Data]
• Replace the CPU/PCI
module board.
0B42 Resource Conflict Configuration error in SETUP. Correct devic e configuration in
SETUP
0B43 Warning: IRQ not
configured Configuration error in SETUP. Correct setting s in SETUP
0B44 Expansion Rom not
initialized Configuration error in SETUP. In SETUP, disable
decompression of expansion
ROM on unnecessary optional
PCI cards.
0B45 System Configuration
Data Write error
• Configuration error in
SETUP.
• CPU/PCI module board is
faulty.
• Reset the setting by
selecting [Yes] at [Reset
Configuration Data]
• Replace the CPU/PCI
module board.
0B47 Missing date and time
synchronization The date and time are
incorrect due to a
communication error between
BMCs.
• Restart the system.
• Re-set the date and time
in SETUP.
If the error persists, replace the
PCI module board.
0B49 BMC Issued Reset
Command, but failed
System Reset
• System cannot be reset by
BMC’s reset command. Replace PCI module board.
0B6E DIMMs are installed out
of order
• DIMM is faulty. Replace DIMM.
0B70 The error occurred
during temperature
sensor reading
• SMBus device is faulty.
• SMBus is faulty. Replace the CPU/PCI module
or back panel board.