5-61
Connect from the Management PC Directly Linked (through Serial port B)
On the management PC that is linked directly to Serial port B of the main unit, perform the steps
below:
112. Start the management PC where MWA is installed. From the Start menu, select [Program]
[NEC MWA] [MWA].
When MWA starts, the initial screen “Remote Control Manager” will appear.
113. Select [Environment] – [Direct Connection Setting] from the [File] menu of NEC MWA
to display the [Direct Connection] dialog box. Configure the following settings:
<Direct Connection>
Port No.: COM port on the management PC to be connected
Baud Rate: 19200
Flow Control: None
114. From MWA’s [File] menu, select [Configuration] command to open [Configuration]
dialog box.
115. Select [New] to display [Select a model] dialog box.
116. Check [Write to FD] and select an applicable model to open [Configuration for ft Series]
dialog box.
Ex) The model name is printed on the front cover like “NEC Express5800/320Lb,”
or “NEC Express5800/320Lb-R.”
117. [Configuration for ft Series] dialog box, specify/register configuration information
including the names of computers to be managed, and then write the information to FD as
the following filename:
<Filename>
CSL_LESS.CFG
118. Right-clicking the server name to open the pop-up menu and select [Property] command
to open [Property] dialog box.
119. When [Property] dialog box appears: specify the items as follows:
<[ID] page>
Connection mode: COM
COM: Direct (cross cable)
120. Right-clicking the server name to open the pop-up menu and select [Open Remote
Console] to open [MWA Remote Console].
After checking to see if the server window is open on [MWA Remote Console], click the
[Connect] button.
121. Hook up the management PC directly to Serial port B of the computer to be managed.
122. Insert NEC EXPRESSBUILDER CD-ROM into the drive of the managed computer and
insert the floppy disk storing the configuration information (CSL_LESS.CFG) into the
FDD drive.