5-20
Supplement
Note the followings when using NEC ESMPRO Agent.
Maintenance-related Functions
When you want to use maintenance-related functions of the NEC Express5800/ft series, contact
your maintenance personnel.
Change of Installation States of CPU and PCI Modules
If you dynamically change the configuration of the CPU or PCI module in the relevant system
during review of the server information by using the data viewer, the message prompting you to
reconstruct the tree of the data viewer will appear. If you click the [Yes] button, the tree is
reconstructed in the data viewer to reflect the change of the system configuration on the data viewer.
Clicking the [No] button does not cause the tree to be reconstructed in the data viewer. If so, the
information in the data viewer may be different from the current system information because the
change of the system configuration is not reflected on the data viewer.
Impact When Module Status Changes
PCI modules, SCSI adapters, SCSI buses, and modules under the SCSI enclosure have impact on
each other. For example, when the “Status” item of a module changes to “fault,” it may be caused
by another module’s error. Therefore, you need to check the status of the other modules based on
alert information.
Status Color after Mounting a Hard Disk
When creating a new mirror, the status of the hard disk and its upper component, SCSI enclosure,
will continue to change frequently after you mount a hard disk until the mirror is completed. During
this process, the status color may turn to abnormal, but when the mirror is created successfully, it
will return normal.
LAN Monitoring Report
The LAN monitoring function defines the line status depending on the number of transmission
packets and the number of packet errors within a certain period. Thus, the LAN monitoring function
may report a line fault or high line load only in a temporary high line impedance state. If a normal
state recovery is reported immediately, temporal high line impedance may have occurred thus there
is not any problem.
Community Authority
Depending on your OS type or its version, settings for community, SNMP service’s security
function, are not made, or default settings of authority are different
To enable the remote shutdown and threshold change functions via NEC ESMPRO Manager, make
settings of community and set its authority to "READ CREATE" or "READ WRITE."
Temperature/Voltage/Fan Sensors Thresholds
The thresholds of temperature/voltage/fan sensors cannot be displayed or modified. However,