Nilfisk-Advance America IVT-1000CR Testing, delivery, installation, 6 — Controls Fig

Models: IVT 1000 CR H IVT-1000CR

1 172
Download 172 pages 768 b
Page 36
Image 36
5 - Testing, delivery, installation

The vacuum has been manufactured with particular attention to the operatorʼs safety.

Comply with the maintenance and technical assistance procedures and information given in this manual. Never use compressed air to clean the machine or its components.

Never open the waste container whilst the vacuum is operating.

Before beginning electrical connection, check that the voltage

and frequency values are those indicated on the data plate of the machine.

Connect the machine to the electricity main with an efficient ground circuit.

Only authorized personnel must be allowed to work on the electrical part of the machine and this must always be disconnected from the electricity main.

Never move the vacuum by pulling the power cable. This may damage the vacuum itself and the operator may be exposed to electric shocks

5 - Testing, delivery, installation

5.1 - Testing

The machine has been tested in our plant in order to ensure that it operates correctly.

Tests on the suction values are carried out during this phase.

This ensures that the vacuum has been optimised according to the job for which it was designed.

5.2 - Delivery and handling

The machine is delivered, in a cardboard box. When receiving the machine check for concealed damage. If damage is discovered, immediately file a complaint with the carrier.

The machine can be stored at temperatures between 0 and 50°C, and 65% relative humidity.

Before storage the machine must always be cleaned in accordance with the instructions.

The machine can be operated in the temperature range -5 to+ 50 °C and 65 % relative humidity.

The delivery packaging should be disposed of in accordancewith the relevant statutory regulations. Dispose of a machine, which is no longer usable, in accordance with the relevant statutory regulations. Only use approved commercially available, non- combustible and non-toxic solvents for the purpose of cleaning the machine Stainless steel body parts and accessories can be cleaned in an autoclave at 121°C

5.3 - Certificate of guarantee

The certificate of guarantee is packed with the vacuum.

5.4- Installing the vacuum

Attention!!

The user shall be responsible for ensuring that installation

complies with the local statutory regulations.

A qualified technician, who has read and understood the instructions herein, must install the equipment.

The floor on which the vacuum must operate should be level, flat and smooth.

If the vacuum is to work in a fixed position, allow ample space all round in order to ensure freedom of movement and make sure that the maintenance staff to operate with ease.

5.5- Connecting to the electricity main

Attention!!

Check that the voltage and frequency values of the electricity main correspond to the values indicated on the data plate described in paragraph 3.1 (data plate) Specialised personnel must carry out all installation and maintenance work on electrical parts.

Connect the equipment to an efficient earth.

Ensure that the electrical supply matches the machine rating plate.

6 — Controls (Fig. 5)

1. On / Off button

2. Vacuum Gauge / Manometer (“H” class machine only)

7 — Starting and stopping

7.1 — Caution

Attention!!

Unauthorized personnel are forbidden to use the vacuum.

7.2 — Starting / Stopping

Check that the machine has been effectively connected to the electricity main. In particular, check that the main voltage and frequency values correspond to those indicated on the data plate. (see fig. 1)

Fit the accessories to the suction inlet. Use the stainless steel clamp to fix the hose to the inlet.

Place the vacuum near the place of use, then lock the wheels by pressing levers downwards.

The machine is switched ON or OFF by pressing the grey button on the upper part of the motor.

8 — Using the vacuum (fig. 7)

8.1 — Correct use of the vacuum

Before using the machine, connect the suction pipe to the inlet as indicated in paragraph 7.2.

Keep long suction pipes as straight as possible.

Do not allow them to bend or twist as this will cause excessive wear and clogging.

When the vacuum is powered, suction is created at the pipe inlet and this sucks in the waste material.

This waste material passes through the pipe and accessories through the inlet “4” until it reaches container “6”.

A Org. Nilfisk dustbag can be used in the standard machine.

To release the container, unfasten the stainless steel clamp and lift off the upper part with the motor/filter section.

Fix the dust bag as follows:

Pierce the dust bag´s perforation and place it in the lower container.

Pull the blue dust bag plastic plate over the suction inlet with both hands.

Unfold the dust bag carefully. Replace the top container and lock the stainless steel clamp.

Note

The suction efficiency depends on the size and quality of the dust bag. Use original Nilfisk bags only. If non- Nilfisk dust bags are used, and airflow restricted,

36

Page 36
Image 36
Nilfisk-Advance America IVT-1000CR Testing, delivery, installation, 6 — Controls Fig, 7 — Starting and stopping