Nokia DNT2Mi sp/mp BF monitoring only with the D2048-type adapters, TS mapping 6,4, port #,3,4

Models: DNT2Mi sp/mp

1 128
Download 128 pages 44.97 Kb
Page 110
Image 110
-BF monitoring (only with the D2048-type adapters)

Data Network Terminal Single-port and Multiport Operating Instructions

-BF monitoring (only with the D2048-type adapters)

-CRC monitoring (only with the D2048-type adapters).

Note

The collection of statistics data is not possible in the ’No frame’ mode.

TS mapping (6,4, port #,3,4)

The placement of time slots to a G.704 frame can be set via this menu. There are two placement alternatives: either in the same way as in the line side or starting from a user given time slot, see the example in Figure 80.

TS use in line

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

0

 

P1

P1

P1

P1 P1

P1

P1 P2

P2

P1 P2

P1

P3

P1 P2

P2

P2

P2 P2

P2

P3

P3 P3

P3

P3

P3 P3

P3

P3

P3

TS mapping in Port1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

TS use in line

P1

P1

P1

P1 P1

P1

P1 P2

P2

P1 P2

P1

P3

P1 P2

P2

P2

P2 P2

P2

P3

P3 P3

P3

P3

P3 P3

P3

P3

P3

From the Port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

menu, select

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1st TS (TS1)

P1

P1

P1

P1 P1

P1

P1 P1 P1

 

 

 

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

and special

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TS (TS16)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TS mapping in Port2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

TS use in line

P1

P1

P1

P1 P1

P1

P1 P2

P2

P1 P2

P1

P3

P1 P2

P2

P2

P2 P2

P2

P3

P3 P3

P3

P3

P3 P3

P3

P3

P3

From the Port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

menu, select

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1st TS (TS1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and special

P2

P2

P2

P2

P2

P2

P2

P2 P2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2

TS (TS32)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TS mapping in Port3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

TS use in line

P1

P1

P1

P1 P1

P1

P1 P2

P2

P1 P2

P1

P3

P1 P2

P2

P2

P2 P2

P2

P3

P3 P3

P3

P3

P3 P3

P3

P3

P3

From the Port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

menu, select

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

as in line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P3

 

 

 

 

 

P3

P3

P3

P3

P3

P3

P3

P3

P3

P3

Figure 80. Time slot mapping example, TS0 locally terminated

110 (128)

© Nokia Corporation

DN01145897

 

Nokia Proprietary and Confidential

Issue 2-0 en

Page 110
Image 110
Nokia DNT2Mi sp/mp BF monitoring only with the D2048-type adapters, CRC monitoring only with the D2048-type adapters