Nokia DNT2Mi sp/mp user manual Default values, Noise margin, Bit error ratio

Models: DNT2Mi sp/mp

1 128
Download 128 pages 44.97 Kb
Page 44
Image 44
Noise margin

 

 

Data Network Terminal Single-port and Multiport Operating Instructions

 

 

 

 

 

Table 3.

Monitoring a line (Continued)

 

 

 

 

 

Line voltage: xx V

 

 

Alternatives: 55 to 155 V + no remote power

 

 

 

 

 

Signal quality

 

 

Signal quality monitored during 1 period of 15 minutes to

Last 15 min

 

 

 

max. 4 (with front panel menus) or 100 (with Q1 menus)

 

 

 

successive periods of 15 minutes.

 

 

 

 

 

 

 

 

Front panel menus give you absolute values and Q1

 

 

 

 

menus both absolute and relative values.

 

 

 

 

 

Signal quality

 

 

Signal quality monitored during 1 period of 24 hours to

Last 24 hours

 

 

max. 4 (with front panel menus) or 30 (with Q1 menus)

 

 

successive periods of 24 hours.

 

 

 

 

 

 

 

 

Front panel menus give you absolute values and Q1

 

 

 

 

menus both absolute and relative values.

 

 

 

 

 

Table 4.

Explanation of noise margin

 

 

 

 

 

Noise margin

 

 

Bit error ratio

 

 

 

 

 

 

 

+15 dB

 

 

 

 

 

+1 dB

 

 

 

Expected BER < 10-7

 

0 dB

 

 

 

Expected BER 10-7

 

6.9Default values

The following default values can be recalled, for example from the Q1 menu path

6,6:

Table 5.

Global parameters

 

 

 

Timing source

Line

 

 

Front panel operation rights

Testing and configuration allowed

 

 

Q1 address *)

2

 

 

Q1 management path

Q1 via line: on

 

 

LM interface: on

 

 

Control and test loop limit

10 minutes

 

 

Q1 password for settings

No protection, password: DNT2Mi

 

 

Equipment ID

DNT2Mi

 

 

Use of front panel

Full menu

 

 

 

44 (128)

© Nokia Corporation

DN01145897

 

Nokia Proprietary and Confidential

Issue 2-0 en

Page 44
Image 44