5.4Work order

Installing DNT2Mi

5.4Work order

First examine the unit and make sure that it has not been damaged during transportation. Also, check that you have the cables needed for connections (mains cable, DTE cable, line cable).

Then proceed according to the steps below:

1.Insert DTE interface units into the DNT2Mi terminal, if needed, refer to Section 5.5.

2.Insert DNT2Mi in a special shelf-like modem subrack or on a wall, if needed, refer to Section 5.7. Otherwise, proceed with the free-standing installation described in Section 5.6.

3.Plug the mains cord into a grounded mains outlet (AC version) or connect the DC power lines (refer to Section 5.8).

4.Connect DNT2Mi to your DTE and to the line.

5.Switch on the power (AC or DC). The modem performs a self test.

6.Adjust the LCD contrast, if needed, refer to Section 5.9.2.

Then proceed to check that the main settings are correct (the settings are described in Chapter 6). The settings can be checked and altered using either the front panel keys and display (Chapter 8) or by using the Q1 connection (Chapter 9).

5.5Inserting DTE interface units

Then proceed according to the steps below: Caution

The equipment is sensitive to static electricity. When handling the units you should follow the general instructions concerning handling of ESD-sensitive equipment. You should always take antistatic precautions (such as a wrist grounding) when handling a plug-in unit once it has been removed from its antistatic packaging.

If the DTE interface units are not pre-inserted or a unit needs to be changed, follow the instructions below.

DN01145897