The conditions listed in Section 5.1 must be fulfilled.

Data Network Terminal Single-port and Multiport Operating Instructions

Table 23. EMC requirements

EN 55022 class B (1994)

EN 55024 (1998)

EN 300386-2 (1998)

Note

The conditions listed in Section 5.1 must be fulfilled.

10.5.3Safety and protection

Concerning protection and safety, DNT2Mi follows the requirements and specifications listed below:

Table 24. DNT2Mi safety and protection

AC power

Electrical safety

EN 60950

supply

 

 

Surge protection

4 kV common mode, 2 kV differential

 

 

 

mode according to EN 61000-4-5

 

 

 

DC power

Dielectric strength

500 VRMS

supply

 

 

Surge protection

1 kV according to EN 61000-4-5

 

 

 

 

Line interface

Safety

EN 60950

 

 

 

 

Surge protection

1.5 kV according to ITU-T Rec. K.21

 

 

 

 

50 Hz common mode

600 VRMS common mode according to

 

test

ITU-T Rec. K.21

 

 

 