Nokia DNT2Mi sp/mp Ethernet, DTE interface options continued, DTE interface adapter units

Models: DNT2Mi sp/mp

1 128
Download 128 pages 44.97 Kb
Page 22
Image 22
Ethernet

Data Network Terminal Single-port and Multiport Operating Instructions

Ethernet

EC PWR

LMI 10Base-T

 

EA

 

EL WL

 

 

CAS

VF

1 8

Figure 10. DTE interface options (continued)

The interface type is selected by installing an appropriate interface unit. You can do this without opening the terminal's case. The interface unit types are given in Table 2.

Table 2.

DTE interface adapter units

 

 

 

 

 

 

Adapter type

 

Electrically

Connector type

Product code

 

 

 

 

 

 

V.11

 

 

V.11, V.10

D37F

DS 62603.11

 

 

 

 

 

 

V.24

 

 

V.28 1)

D25F

DS 62602.11

V.35

 

 

V.35, V.28

34F

DS 62604.11

 

 

 

 

 

 

X.21

 

 

V.11

D15F

DS 62605.11

 

 

 

 

 

 

G.703/64k

 

 

G.703

D15F

DS 62609.11

 

 

 

 

 

 

G.703/2M

 

 

G.703

SMBM, BNC or

DS 62607.11

 

 

 

 

D9F

 

 

 

 

 

 

 

G.704/2M

 

 

G.703

SMBM or D9F

DS 62608.11

 

 

 

 

 

 

EIA-530-A

 

 

V.11, V.10

D25F

DS 62610.11

 

 

 

 

 

 

ET

 

 

10Base-T

RJ45

E66210.02

 

 

 

 

 

(Router/Bridge)

 

 

 

 

 

E66210.22 (Bridge)

 

 

 

 

 

 

D2048

 

 

G.703

RJ45

E62628.01

 

 

 

 

 

 

D2048

 

 

G.703

RJ45 or BNC

E62628.10

 

 

 

 

 

 

D2048

 

 

G.703

RJ45 or SMB

E62628.11

 

 

 

 

 

 

VF

 

 

Analogue 2/4-

RJ45

E62612.02

 

 

 

wire

 

 

 

 

 

 

1) In accordance with the ITU-T Recommendation V.28, this type of electrical

interface can be used up to 19.2 kbit/s. With proper cabling, however, operation up to

64 kbit/s is possible.

 

 

 

 

 

 

 

 

 

22 (128)

© Nokia Corporation

DN01145897

 

Nokia Proprietary and Confidential

Issue 2-0 en

Page 22
Image 22
Nokia DNT2Mi sp/mp Ethernet, DTE interface options continued, DTE interface adapter units, Adapter type, Electrically