Nokia DNT2Mi sp/mp user manual Front, Automatic, panel, management, control, PRBS tests, 5,2,#,4

Models: DNT2Mi sp/mp

1 128
Download 128 pages 44.97 Kb
Page 53
Image 53
PRBS tests

Maintaining DNT2Mi

Table 14.

Tests available for DNT2Mi (Continued)

 

 

 

 

 

 

 

Front

Q1

Automatic

Note

 

panel

management

control

 

 

 

 

 

 

PRBS tests

Port TR

Tx-Rx test (TR)

 

See Figure “PRBS (29-

ITU-T V.52 29-1 test pattern

test

 

(5,2,#,4)

 

1) test (transmitter /

 

 

 

 

Transmitter and receiver

 

 

 

 

receiver)” after this

 

 

 

 

table.

towards the line.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remotely controlled

Port RL

 

V.xx Circuit 140

Automatic control can

network test loop

test

 

 

or X.21 loop 2

be disabled by setting

ITU-T X.150 loop 2 at remote

 

 

 

command

circuit 140 in the ‘Not in

 

 

 

 

use’ state at the local

end

 

 

 

 

 

 

 

 

port.

Data coming from the line is

 

 

 

 

 

 

 

 

Establishment of the

looped back to the line.

 

 

 

 

 

 

 

 

requested loop can be

Activated at the local port

 

 

 

 

 

 

 

 

disabled by setting

and a loop is established at

 

 

 

 

 

 

 

 

“Remote loop not

the remote end.

 

 

 

 

 

 

 

 

allowed” at the remote

 

 

 

 

 

 

 

 

 

 

end.

 

 

 

 

 

See Figure “Remotely

 

 

 

 

 

controlled network test

 

 

 

 

 

loop” after this table.

 

 

 

 

 

Remotely controlled

Port RLTR

 

 

Establishment of the

network test loop with

test

 

 

 

requested loop can be

PRBS test pattern

 

 

 

 

disabled by setting

ITU-T X.150 loop 2 at remote

 

 

 

 

“Remote loop not

 

 

 

 

allowed” at the remote

end and ITU-T V.52 29-1 test

 

 

 

 

 

 

 

 

end.

pattern

 

 

 

 

 

 

 

 

See Figure “Remotely

Transmitter and receiver at

 

 

 

 

 

 

 

 

controlled network test

the local port.

 

 

 

 

 

 

 

 

loop with PRBS test

 

 

 

 

 

 

 

 

 

 

pattern” after this table.

 

 

 

 

 

 

LOCAL DNT

REMOTE DNT

PORT 1

DTE

DTE

PORT 1

LINE

 

BLOCK

 

PORT 2

DTE

 

DTE

PORT 3

 

PORT 2

PORT 3

DTE

DTE

Figure 28. Network test loop (all ports)

DN01145897

© Nokia Corporation

53 (128)

Issue 2-0 en

Nokia Proprietary and Confidential

 

Page 53
Image 53
Nokia DNT2Mi sp/mp Front, Automatic, panel, management, PRBS tests, 5,2,#,4, Remotely controlled, network test loop