6.8Measurements

Commissioning DNT2Mi

6.8Measurements

After all the settings have been checked, we recommend that you carry out a line quality and a BER test.

Note

Before starting the BER test, reset all statistics and error counters. Read statistics and error counters after the BER test.

Noise margins, Rx and Tx line levels, and attenuations (Q1: 7,1...3)

Establish a link between two units. After the line is up, check the noise margin, Rx level, and line attenuation from the Measurements menu.

You can use Table 28 in Appendix A to mark down the results for line attenuation.

Bit error rate test

We recommend you to perform a five-minute bit error rate (BER) test. For the test, you need an external test equipment.

You can use Table 27 in Appendix A to mark down the results.

After the tests

Check that all alarms have disappeared and the statistics are still correct.

Table 3.

Monitoring a line

 

 

 

Tx level

 

 

Line 1 or 2: xx dBm

xx = +7.5 to +14.5 dBm

 

 

 

Rx level

 

 

Line 1 or 2: xx dBm

xx = +14.5 to -26 dBm

 

 

Noise margin

 

Line 1 or 2: xx dB

xx = 0 to +15 dB

 

 

 

Attenuation

 

 

Line 1 or 2: xx dB

xx = 0 to 41 dB

 

 

 