Nokia DNT2Mi sp/mp Global parameters Continued, Line parameters, Multiplexer parameters

Models: DNT2Mi sp/mp

1 128
Download 128 pages 44.97 Kb
Page 45
Image 45
Table 5. Global parameters (Continued)

Commissioning DNT2Mi

Table 5. Global parameters (Continued)

Use of front panel keys

In use

 

 

Q1 rate *)

4800 bit/s

 

 

*) = Recalling the default values does not change the values set for the Q1 management parameters. The original values for these parameters can be recalled by recalling the factory settings, refer to Section 6.10.

Table 6.

Line parameters

 

 

 

Line interface

STU-R rate adaptive, 2-wire

 

 

Power backoff

ON

 

 

Bit error alarm limit

10-6

Table 7. Multiplexer parameters

Use of time slots

No time slots connected

Table 8.

Port parameters, V-series (V.11, V.28, V.35 or EIA-530-A)

 

 

 

Port rate

 

n x 64k (n=1)

 

 

Use of V.110 rate adaptation in

Not in use

port 2 or 3

 

 

 

 

In port 2 or 3

9600 kbit/s, Synchronous

 

 

Remote loop detection

Allowed

 

 

Externally caused alarms

Disabled (not to be seen through Q1).

 

 

However, even if these alarms are disabled, they

 

 

cause front panel alarms.

 

 

Rx timing (CT103)

DCE source (CT114)

 

 

 

CTS use

 

Not in use

 

 

 

CTS

 

On

 

 

 

DCD

 

Follows line synchronisation

 

 

 

DSR

 

On

 

 

 

Circuit 140

 

Disabled

 

 

 

Circuit 141

 

Disabled

 

 

 

DN01145897

© Nokia Corporation

45 (128)