9.3.3Timing source (6,2)

Data Network Terminal Single-port and Multiport Operating Instructions

Q1 address (6,1,2)

The Q1 address must be selected before DNT2Mi can be accessed using management.

The address can range from 0000 to 4095. The last address (4095) is a universal address that cannot be selected by the Q1 manager.

Q1 management path (6,1,3)

A Q1 management source is selected from this menu. The source can either be:

Q1 via line, EOC

Local management interface

Q1 via Port1 (only with G.704 adapter).

9.3.3Timing source (6,2)

This menu allows you to select a source for timing. The timing alternatives are:

Internal

Line

Port1

Transparent.

Figure 73 illustrates the principle of each alternative.

The timing of circuit 103 can be set either by the clock from DTE (113) or by the clock of the equipment (114). See Figures 78 and 79 in Section 9.3.5.

98 (128)

© Nokia Corporation

DN01145897

 

Nokia Proprietary and Confidential

Issue 2-0 en