132Appendix A Metro Ethernet Routing Switch 8600 module technical specifications

Connector types

Ethernet Management port:

RJ-45 connector wired as MDI (see "Pin assignments: 8692omSF module" (page 132))

Console port:

DB-9 connector (see "Pin assignments: 8692omSF module Console port" (page 133))

Modem port:

DB-9 connector (see "Pin assignments: DTE to DCE" (page 133))

Cable specifications

Ethernet Management port:

Category 3, 4, or 5 UTP cable (10 Mb/s operation)

Category 5 UTP cable (100 Mb/s operation)

Console port:

RS-232 cable

Modem port:

DTE-to-DCE cable (straight or transmit cable)

Management port

The Management port is a 10/100 Mb/s Ethernet port implemented on an RJ-45 connector wired as an MDI connection.

"Pin assignments: 8692omSF module" (page 132) shows the pin assignments for this connector.

Pin assignments: 8692omSF module

Connector

Pin number

Signal

 

 

 

 

1

Output transmit data + (TX+)

 

 

 

 

2

Output transmit data - (TX-)

 

 

 

 

3

Input receive data + (RX+)

 

 

 

 

6

Input receive data - (RX-)

 

 

 

 

4, 5, 7, 8

Not used

 

 

 

Console serial port

The Console serial port is implemented as a DB-9 connector. This port can operate as a data terminal equipment (DTE) or data communication equipment (DCE) device. Use the switch to the left of the port to set the port to DTE (right) or DCE (left). Default settings for this port are 9600 bits/s, 8 data bits, no parity, and one stop bit.

Nortel Metro Ethernet Routing Switch 8600

Installation — Modules

NN46220-306 02.02 Standard

4.27 July 2008

Copyright © 2005-2007, Nortel Networks

Page 132