106Appendix A Metro Ethernet Routing Switch 8600 module technical specifications

Gigabit Ethernet minimum distance ranges

Transceiver/

Diameter

Modal

Advertised

Average

Average

Optical

Fiber type

(microns)

Band-

Range

Optical

Minimum

Wave-

(see Note 1)

 

width

(meters)

Transmit

Receiver

length

 

 

(MHz/

 

Power

Sensi-

(nm)

 

 

km)

 

(dBm)

tivity

 

 

 

 

 

 

(dBm)

 

 

 

 

 

 

 

 

1000BaseSX

62.5

160

2 to 220

-9.5 to -4

-17

850

MMF

 

 

(see Note 2)

 

 

 

 

 

 

 

 

 

 

1000BaseSX

62.5

200

2 to 275

-9.5 to -4

-17

850

MMF

 

 

(see Note 3)

 

 

 

 

 

 

 

 

 

 

1000BaseSX

50

400

2 to 500

-9.5 to-4

-17

850

MMF

 

 

 

 

 

 

 

 

 

 

 

 

 

1000BaseSX

50

500

2 to 550

-9.5 to-4

-17

850

MMF

 

 

(see Note 4)

 

 

 

 

 

 

 

 

 

 

1000BaseLX

62.5

500

2 to 550

-5.2 to 0

-22

1300

MMF

 

 

(see Note 5)

 

 

 

 

 

 

 

 

 

 

1000BaseLX

50

400

2 to 550

-5.2 to 0

-22

1300

MMF

 

 

(see Note 5)

 

 

 

 

 

 

 

 

 

 

1000BaseLX

50

500

2 to 550

-5.2 to 0

-22

1300

MMF

 

 

(see Note 5)

 

 

 

 

 

 

 

 

 

 

1000BaseLX

9

N/A

2 to 10000

-5.2 to 0

-22

1300

SMF

 

 

 

 

 

 

 

 

 

 

 

 

 

1000BaseXD

9

N/A

Up to 50 Km

-5.2 to 0

-24

1550

SMF

 

 

 

 

 

 

 

 

 

 

 

 

 

1000BaseZX

9

N/A

Up to 70 Km

0 to 5.2

-22

1550

SMF

 

 

 

 

 

 

 

 

 

 

 

 

 

1000BaseAPD

9

N/A

Up to 96 Km

+2 to +6

-28

1550

SMF

 

 

(see Note 6)

 

 

 

 

 

 

 

 

 

 

Note 1: Multimode fiber = MMF; single mode fiber = SMF

Note 2: The TIA 568 building wiring standard calls for 160/500 MHz-Km multimode fiber

Note 3: The international ISO/IEC 11801 building wiring standard calls for 200/500 MHz-Km multimode fiber

Note 4: The ANSI Fibre Channel specification calls for 500/500 MHz/Km 50 micron multimode fiber and 500/500 fiber will be proposed for addition to ISO/IEC 11801

Note 5: Using LX optics on multimode fiber may require the use of DMD-compensating patch cords

Note 6: CWDM GBICs require a minimum of 5dB attenuation between transmitter and receiver. Safety margin includes normal 3dB plus 2.4 Sigma value for CWDM variation. Maximum distance is only achievable without OADM and OMUX in the path

Nortel Metro Ethernet Routing Switch 8600

Installation — Modules

NN46220-306 02.02 Standard

4.27 July 2008

Copyright © 2005-2007, Nortel Networks

Page 106
Image 106
Nortel Networks 8003AC, 8005DC 1000BaseSX 62.5 160 850, See Note 1000BaseSX 62.5 200 850, See Note 1000BaseSX 400 To-4 850