92Installing Metro Ethernet Routing Switch 8600 modules and connecting equipment

 

 

 

Recommended

Minimum

Maximum

Module

Port

Connector

cable

cable

cable type

 

 

 

length

length

 

 

 

 

 

 

 

 

 

 

8683POSM

OC-3

MT-RJ

9/125 µm

None

9.3 mi

OC-3

 

 

single-mode

 

(15 km)

 

 

 

fiber-optic cable

 

 

 

 

 

 

 

 

 

OC-3

MT-RJ

62.5/125 µm

None

1.24 mi

 

 

 

multimode

 

(2 km)

 

 

 

fiber-optic cable

 

 

 

 

 

 

 

 

8683POSM

OC-12

Duplex SC

9/125-µm

None

9.3 mi

OC-12

 

 

single-mode

 

(15 km)

 

 

 

fiber-optic cable

 

 

 

 

 

 

 

 

 

OC-12

Duplex SC

62.5/125 µm

None

1640 ft

 

 

 

multimode

 

(500 m)

 

 

 

fiber-optic cable

 

 

 

 

 

 

 

 

8683XLR

10GBase-

Duplex LC

See Note 5

None

See Note 5

 

LR port

 

 

 

 

 

 

 

 

 

 

8683XZR

10GBaseR

Duplex LC

See Note 5

None

See Note 5

 

port

 

 

 

 

 

 

 

 

 

 

8691omSF

Ethernet

RJ-45

EIA Category 3,

None

328 ft

 

Manage-

 

4, or 5 UTP for

 

(100 m)

 

ment port

 

10 Mb/s operation;

 

 

 

 

 

EIA Category 5

 

 

 

 

 

UTP required

 

 

 

 

 

for 100 Mb/s

 

 

 

 

 

operation

 

 

 

 

 

 

 

 

 

Serial ports

DB-9

RS-232

 

 

 

 

 

 

 

 

8692omSF

Ethernet

RJ-45

EIA Category 3,

None

328 ft

 

Manage-

 

4, or 5 UTP for

 

(100 m)

 

ment port

 

10 Mb/s operation;

 

 

 

 

 

EIA Category 5

 

 

 

 

 

UTP required

 

 

 

 

 

for 100 Mb/s

 

 

 

 

 

operation

 

 

 

 

 

 

 

 

 

Serial ports

DB-9

RS-232

 

 

 

 

 

 

 

 

Note 1: Ports on the 8632TXE, 8632TXM, 8648TXE, and 8648TXM modules are wired as MDI-X. Use straight-through cables to connect these ports to MDI connections such as workstations or servers. Use crossover cables to connect these ports to other MDI-X connections such as hubs or other switches.

Note 2: Depends on installed GBIC model; for specifications, see Nortel Installation — SFP, XFP, and GBIC Hardware Components (NN46225-301).

Note 3: Depends on installed SFP model; for specifications, see Nortel Installation — SFP, XFP, and GBIC Hardware Components (NN46225-301).

Nortel Metro Ethernet Routing Switch 8600

Installation — Modules

NN46220-306 02.02 Standard

4.27 July 2008

Copyright © 2005-2007, Nortel Networks

Page 92
Image 92
Nortel Networks 8004AC, 8005DC, 8003AC, 8004DC, 8005AC 8683POSM OC-3, 125 µm None OC-3 Single-mode 15 km Fiber-optic cable