RTU-292 Operations Manual

Table 2-7

Full/Half Duplex

 

 

SW2-8

Full/Half Duplex

Off

Full Duplex

 

 

On

Half Duplex *

 

 

2.8.10 SERIAL PORT BAUD RATE

Internal dipswitches SW1-1 and SW1-2 on the Main board configure the RS-232 baud rate of the unit's serial port as shown in the table below. The factory setting is 9600 Baud.

 

Table 2-8

Baud Rate

 

 

 

 

SW1-1

SW1-2

 

Baud Rate

Off

Off

 

300

 

 

 

 

On

Off

 

1200

 

 

 

 

Off

On

 

4800

On

On

 

9600 *

 

 

 

 

2.8.11 RADIO CONTROL MODE

Dipswitch SW1-3 enables the RTU-292 to be put into the Radio Control Mode via one of its DTMF commands. In this mode the RTU-292 can be used to relay radio control commands via its RS-232 port to a companion Motorola URC-200 radio. The factory default disables this mode, with SW1-3 set to OFF. See also Tables 3-1 and 3-3.

Table 2-9

Radio Control Mode

 

 

SW1-3

Radio Control

Off

Disabled *

On

Enabled

 

 

2-9

JPS Communications, Inc.

Page 25
Image 25
Nortel Networks RTU-292 operation manual SW2-8 Full/Half Duplex Off Full Duplex, Baud Rate, Radio Control Mode