RTU-292 Operations Manual

5.3.15 Time Command

TIME <hhmmss> <CR>

This command is used to check or set the time on the RTU-292 internal clock. If no parameters are given the command simply returns the time/date. The parameter format is hour (00-23), minutes (00- 59), seconds (00-59). The time is set and displayed in 24-hour format. Note: the Call Logging Feature

must be enabled before use. See 3.7.12.

.

Expected Response: Time/Date Response.

Examples:

TIME <CR> ; Command requesting the current time and date from the RTU-292.

%01-MAR-98 11:05:20 E0 <CR> ; Status returned indicating that the date is March 1st ‘98, and the time

is

;11:05 and 20 seconds in the morning.

TIME 141830 <CR>

; Command to set the time to 2:18 and 30 seconds in the afternoon.

%05-DEC-97 14:18:30 E0 <CR> ; Status returned indicating that the date is December 5th ‘97, and the

time is

; 2:18 and 30 seconds in the afternoon.

5.3.16 Software Version Command

VER <CR>

This command is used to determine the version of the RTU-292 firmware. The command requires no parameters.

Expected Response: Version Response.

Example:

 

VER <CR>

; Command sent to the RTU-292.

%VER 2.00 E0 <CR>

; Status returned from the RTU-292.

This status indicates that the CPU software version is 2.00.

JPS Communications, Inc.