Nortel Networks Interconnect Information, RTU-292 Operations Manual, 12 Local Phone Enable

Models: RTU-292

1 116
Download 116 pages 40.93 Kb
Page 27
Image 27
Table 2-12Local Phone Enable

RTU-292 Operations Manual

Table 2-12Local Phone Enable

SW1-7

Local Phone

Off

Disabled

 

 

On

Enabled

 

 

 

Table 2-13Local Phone Ringthrough

 

 

SW1-8

Ringthrough

Off

Disabled *

 

 

On

Enabled

2.8.15 TRANSMIT LEVEL SET-UP MODE

Dipswitch SW2-7 is used by the factory to enable a special set-up mode. See section 2.10 for instructions. This switch must remain Off (Normal Mode) for standard operation.

Table 2-14TX Level Set-up Mode

SW2-7

Set-up Mode

Off

Disabled *

 

 

On

Enabled

 

 

2.8.16 MISCELLANEOUS JUMPERS

The following jumpers are installed in the factory as required. This explanation is provided in case they are accidentally removed and must be replaced.

Security Option Jumpers on J5. Unless a Security Option Interface Cable is plugged into J5 on the Main Board, jumper plugs must be installed at J5 pins 4&5 and pins 7&8.

Option Jumpers on J10. If the Option tray is not installed, a jumper must be placed at pins 13&14 of J10. This jumper allows normal operation of the unit when the Options Tray and the Options Interface Board are not installed.

2.9 INTERCONNECT INFORMATION

Interconnect cables should be shielded for best performance. Figure 2.6, Interface Details, gives simplified interconnect information about the unit.

2-11

JPS Communications, Inc.

Page 27
Image 27
Nortel Networks Interconnect Information, RTU-292 Operations Manual, 12 Local Phone Enable, SW1-7, SW1-8, Ringthrough