Orion SAP-UR184EH, SAP-UR94EH, TRUE Electrical Data, Tubing Length And Elevation Difference Limits

Models: SAP-UR94E SAP-CR184EA SAP-UR94EH SAP-CR94E SAP-CR224EA SAP-CR184EHA SAP-UR224E SAP-CR94EH SAP-CLR184EA SAP-UR184E SAP-UR124E SAP-CR124E SAP-UR184EH TRUE

1 52
Download 52 pages 12.93 Kb
Page 3
Image 3
ELECTRICAL DATA
(go on page 4)

Installation site selection - Indoor unit

AVOID

Direct sunlight.

Nearby heat sources that may affect unit performance.

Areas where leakage of flammable gas may be expected.

Locations where large amounts of oil mist may occur (such as in kitchen or near factory equipment) because oil contamination can cause operation problems and may deform plastic surfaces and parts of the unit.

Unsteady locations that will cause noise or possible water leakage.

Locations where the remote control unit will be splashed with water or affected by dampness or humidity.

To make holes in areas where electrical wiring or conduits are located.

DO

Select an appropriate position from which every corner of the room can be uniformily cooled.

Select a sufficiently strong location to support the weight of the unit.

Select a location where tubing and drain hose have the shortest run to the outside.

Allow access for operation and maintenance as well as unrestricted air flow around the unit.

Installation site selection - Outdoor unit

 

AVOID

 

• Heat sources, exhaust fans.

EG

Direct sunlight.

Damp, humid or uneven locations.

To make holes in areas where electrical wiring or conduits are located.

DO

Choose places as cool as possible and well ventilated.

use lug bolts or equal to bolt down the unit, reducing vibration and noise.

ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)

Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with foamed polyethylene (min. thickness 8mm).

MODEL

NARROW TUBE

LARGE TUBE

OUTER DIAMETER

MIN. THICKNESS

OUTER DIAMETER

MIN. THICKNESS

 

UR9X - UR12X

6,35 mm

0,8 mm

9,52 mm

0,8 mm

UR18X

6,35 mm

0,8 mm

12,7 mm

0,8 mm

UR22X

6,35 mm

0,8 mm

15,88 mm

1 mm

PVC pipe for condensate drain pipe (ø int.18mm) in lenght suitable to let the condensate flow into the outside drainage.

Anti-freeze oil for flare connections (about 30g.).

Electric wire: use insulated copper wires of size and length as shown in the table “ELECTRICAL DATA” and at paragraph “SYSTEM WIRING DIAGRAMS”.

ELECTRICAL DATA

LENGTH, WIRE SIZE AND DELAYED FUSE

MODEL

Power supply wiring length

mm2

Power line length

mm2

Control line length

mm2

Delayed fuse

 

(A) m

 

(B) m

 

(C) m

 

 

CR9X

80

2

80

2

160

0,75

10 A

140

3,5

140

3,5

 

 

 

 

CR12X

50

2

50

2

160

0,75

10 A

90

3,5

90

3,5

 

 

 

 

CR/CLR18X

22

2,5

30

2,5

30

2,5

20 A

CR22X

16

2,5

30

2,5

30

2,5

20 A

TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS

MODEL

MAX. ALLOWABLE

LIMIT OF TUBING

LIMIT OF ELEVATION

REQUIRED AMOUNT OF

TUBING LENGTH AT

LENGTH

DIFFERENCE

ADDITIOONAL

 

SHIPMENT

(m)

H

REFRIGERANT

 

(m)

(m)

(g / m)*

UR9X

7,5

15

7

15

 

 

 

 

 

UR12X

7,5

20

7

25

 

 

 

 

 

UR18X - 22X

7,5

30

7

25

 

 

 

 

 

 

 

 

 

 

* For every meter of tube more than standard lenght at shipment, add refrigerant as shown in the table. No additional charge of compressor oil is necessary.

3

Page 3
Image 3
Orion SAP-UR184EH, SAP-UR94EH, TRUE, SAP-CR94EH, SAP-CR184EHA Electrical Data, Tubing Length And Elevation Difference Limits