Setting the functions
This section describes how the unit’s functions are set. The following functions can be set.
Setting of the remote camera operations
Registration of functions in the USER buttons
Setting the speed at which to move to the preset memory setting position
Setting the control items used when preset data is executed
Controlling the peripheral devices connected to the remote cameras
• ND filter | • Wiper |
• AC adapter | • Heater, fan |
• Halogen lamp | |
• Defroster |
|
Assignment of preset data when emergency interrupts occur
Locking of button operations
The settings are established using the [SETUP] menu. First, the basic menu operations will be described.
1 Set the MENU button to ON.
Press the MENU button to light its indicator.
2 Set the PRESET MEMORY/MENU 9 button (SETUP) to ON.
When the button is pressed and its indicator lights, the [SETUP] menu is displayed on the LCD panel.
[1]USER ▼
3 Turn the F1 dial to display the target menu item, and press the F1 dial.
For details on the [SETUP] menu items, refer to the “Table of menu items”.
[4]OPERATE
Press the F1 dial.
1.PAN DIR | ▼ |
NORMAL
4 Turn the F1 dial to select the target menu item.
1 | .PAN | DIR | ▼ |
|
| NORMAL |
|
|
| Turn the F1 dial. | |
2 | .TILT | DIR |
|
|
| NORMAL |
|
5 Turn the F2 dial to select the setting.
Then press the F2 dial to change the setting.
2.TILT DIR
NORMAL
Turn the F2 dial, and then press it.
2.TILT DIR
REVERSE