Panasonic AW-RP50N operating instructions Setting the image output and image input

Models: AW-RP50N

1 48
Download 48 pages 18.08 Kb
Page 29
Image 29
Setting the image output and image input

Setting the functions when the unit is linked with the switcher

Set the various functions to be used when the unit is linked with the switcher.

Setting the image output and image input

This setting establishes the correlation between the image output (remote camera) and image input (switcher).

By establishing the setting, the switcher is notified if a remote camera which has been set is selected when the remote cameras have been selected by the unit.

1 Set the MENU button to ON.

Press the MENU button to light its indicator.

2 Set PRESET MEMORY/MENU 10 button (SYSTEM) to ON.

When the button is pressed and its indicator is lighted, the [SYSTEM] menu is displayed on the LCD panel.

[1]CAMERA CTL ▼

3 Turn the F1 dial, display the SW ASSIGN menu, and press the F1 dial.

[4]SW ASSIGN

Press the F1 dial.

1.INPUT1 ▼ CAM1 Manual background

4 Turn the F1 dial to select the input line of the switcher.

1.INPUT1 ▼ CAM1 Manual background

Turn the F1 dial.

2.INPUT2 Manual background CAM1 Manual background

5 Turn the F2 dial, select the remote camera, and then press the F2 dial to enter the selection.

2.INPUT2 Manual background CAM1 Manual background

Turn the F2 dial, and then press it.

2.INPUT2 Manual background CAM2 Manual background

The switcher has five input lines: INPUT1 to INPUT5.

Take the above steps to set the remote cameras for the input lines, and then operate the remote cameras.

 Select “NoAsign” if the switcher is not to be notified of the correlation setting when the remote cameras have been selected.

29