Operating Instructions
Remote Camera Controller
Model No. AW-RP50N
Operations and Settings
Contents
How to turn the power of the remote cameras on
Selecting the settings for a selected remote
Operating the menu items of the selected remote
Network-relatedprecautions
Before use
Overview
Concerning the Operating Instructions
How to turn the power of the remote cameras on
2Set PRESET MEMORY/MENU 8 button CAMERA to ON
1Select the remote camera
1Set the MENU button to ON
Setting and operating the preset memories
Registering data in the preset memories
3Press the STORE button
Memo
Executing the preset data
Deleting the preset memory data
1Press the DELETE button
Setting and operating the preset memories
Setting the gain
Setting the pedestal
3Turn the F1 dial to select the setting
3Turn the F2 dial to select the setting
Setting the R and B gain values
Setting the R and B pedestal
RGAIN ±000 BGAIN ±000
RPED
Setting the white balance
Selecting the white balance mode
AWB MODE AWB B
1Set the MENU button to ON
Automatically adjusting the white balance
AWB MODE AWB A
Memo
1Set the MENU button to ON
3Set the MENU button to ON
3Turn the F1 dial to select ATW
1Set the MENU button to ON
Setting the black balance
Automatically adjusting the black balance
Manually adjusting the black balance
2Set the MENU button to ON
Setting the shutter speed
Setting the detail
2Set the PRESET MEMORY/MENU 6 button DETAIL to ON
3Turn the F1 dial to select the shutter mode
Setting the shooting mode
Specifying the color bars
3Turn the F1 dial to select the shooting mode
SCENE MANU1 MODE CAM
Table of operations
Remote camera
Menu ON/OFF
Cursor movements
Setting the USER buttons
2Set the PRESET MEMORY/MENU 9 button SETUP to ON
Registering functions in the USER buttons
3Press the F1 dial
Setting the functions
4Turn the F1 dial to select the target menu item
4OPERATE
1.PAN DIR
Setting the remote camera operations
Setting the panning direction
Setting the tilting direction
Setting the zooming direction
5.SPEED WITHZ Off
6.SPEED TARGET R/T/Z/F
P/T/Z/F
Setting the functions
Setting the PAN/TILT lever inclination and speed
7.FOCUS/IRIS NORMAL
8.P/T CURV
Setting the functions
1.DIAG SPEED
2.SCOPE MODE A
Setting the functions
Mode
Setting the upper limit
Setting the lower limit
Display that appears with the AW-HE50
3.LIMIT UP Off
Setting the left limit
Setting the right limit
5.LIMIT LEFTOff
5.LIMIT LEFTOn
3.HOMEPOSITION SET
Setting the functions
6FUNCTION
Controlling an ND filter
1.ND FILTEROff
Controlling an AC adapter AW-PS300A
Adjusting the minimum pan/tilt start speed
Adjusting the minimum lens zoom start speed
1.P/T MIN SPEED START
2.Z MIN SPEED
Setting the preset numbers
Setting button operation enable or disable
1.MENU CONTROL ENABLE
Locking the button operations
Linking the unit with the switcher
Switcher network settings
2Set PRESET MEMORY/MENU 10 button SYSTEM to ON
1Set the MENU button to ON
Setting the image output and image input
1CAMERA CTL
3SW ASSIGN
1.INPUT1 CAM1
Switcher settings
2Set PRESET MEMORY/MENU 9 button SETUP to ON
Linking the unit with the switcher
1Set the MENU button to ON
Bus setting
Focus assist setting
Camera information setting
3.BUS AUX
OA tally setting
PAN/TILT lever control setting
6.TALLY IP Off
7.P/T LEVER
Setting all the information displays together
Linking the unit with the switcher
2Set PRESET MEMORY/MENU 9 button SETUP to ON
1Set the MENU button to ON
Setting each information item to be displayed
Remote camera alarm information
9.ALARM Off
Video format
Checking the equipment alarm information
8ALARM
1.POWER NO ALARM
NO ALARM
Set PRESET MEMORY/MENU 10 button SYSTEM to ON
5Press the F2 dial to initialize the settings
1.INITIALIZE SETUP
SETUPSETTING
Control interface for external devices
TALLY/GPI
D-sub 15-pin,female, inch thread
Example of GPI Out connections
RP setting tool
Installing the software
IP settings
Software provided on the CD-ROM
Auto IP setting
Changing the IP addresses
Changing the camera numbers
1Click RENEW
Alarm displays
Displaying the camera names
Initializing the IP addresses
Acquiring information
Saving the setting files
Saving and loading data
2Input the filename, and click Save
RP setting tool
Loading the setting files
Saving the log files
1Click File
2Select the file, and click Open
Table of menu items
Setting
Button
Menu item
Setting
Table of menu items
Button
Menu item
Setting
Table of menu items
Button
Menu item
Setting
Table of menu items
Button
Menu item
F0410Y0
Operating Instructions Basics
Remote Camera Controller
Model No. AW-RP50N
Safety precautions
THIS APPARATUS MUST BE EARTHED
IMPORTANT SAFETY INSTRUCTIONS
Safety precautions
indicates safety information
Network-relatedprecautions
Accessories
Installation precautions
Operating precautions
Network-relatedprecautions
Before use
Overview
Concerning the Operating Instructions
Characteristics
Compact design
IP connection and serial connection supported
IP connection
Accessories
Pan-tiltheads and cameras supported
Pan-tiltheads supported
Required personal computer environment
Installation precautions
Connecting the power supply
Choosing the best installation location
Handle carefully
Operating precautions
When the product is to be discarded
Handle carefully
Avoid humidity and dust
POWER indicator POWER
ALARM indicator ALARM
Parts and their functions
Control panel
PRESET MEMORY/MENU buttons PRESET MEMORY/MENU
CAMERA OSD button CAMERA OSD
EXIT button EXIT
USER buttons USER1, USER2
Button indicator ON Auto focusing
Button indicator OFF Manual focusing
When it is turned clockwise
Button indicator ON Auto iris
POWER switch POWER
Ground terminal SIGNAL GND
SERVICE switch SV/NM
LAN connector LAN RJ-4510BaseT/100BaseTX
1Turn on the unit’s power
4Adjust the zoom
5Adjust the lens iris
6Adjust the focus
Basic operations for the menus
Select the target menu
Set the MENU button to ON
Network settings
Setting the unit
6Turn the F2 dial, and select the setting
7Press the F2 dial, and change the setting
Setting the IP address
Setting the subnet mask
Setting the default gateway
Setting the MAC address
Connections
Example of IP connections
Connections with the AW-HE50and AW-HS50
SDI video signal
Example of serial connections
Connection with the AW-HE50
Connection with the AW-HE100
Connections
Connections with the AW-PH400and camera
Switch settings
Connections
Zoom lens
Connections with the AW-PH405and camera
Connections
Zoom lens
10BASE-TUTP category 5 straight cable
Connection with the AW-PH650
Connections
RJ-45relay adapter
10BASE-TUTP category 5 straight cable
Settings for connection with the remote cameras
Serial connection
IP connection
1.CAM1 Serial
When setting the IP addresses for the first time
2 On the SYSTEM menu, select AUTO SET
Connections
SET UP IP ttttt
SET UP IP COMPLETE
SET UP IP SET UP ERR
C 20/20 S 1/1 C/S OVER! YES
1.AUTO SETUP KEEP
Connections
2 On the SYSTEM menu, select AUTO SET
Memo
SET UP IP IP DuplicateERR
SET UP IP ttttt
SET UP IP COMPLETE
SET UP IP SET UP ERR
Setting the IP addresses
Changing the IP addresses of the remote cameras
Selecting the camera group
1.GROUP SELECT
Changing the IP address of the switcher
Changing the camera numbers
Clearing the IP address control tables
3Press the F2 dial to enter the IP address
2Set the PRESET MEMORY/MENU 8 BUTTON CAMERA to ON
Selecting the remote cameras to be operated
1Set the MENU button to ON
3Press the F1 dial
Maintenance
to cool down
Appearance
Unit mm inch
189 7-7/16
210 8-1/4
Specifications
Input/Output connector
Power requirements: DC 12 V 10 %
Power consumption DC 12 V, 0.5 A
F0410Y0